42
Service Manual – SC500
04 - Control System
(Figure 20) Drive connections (2-way male faston T-connectors, 6.3x0.8 – spacing 7.4mm)
Ref.
Description
Controller
in/out
V ref.
I max.
Connected to
M1
Drive system motor +
out
0-24V
45A
M3+
M2
Drive system motor -
out
0-24V
45A
M3-
Figure 20:
(Figure 21) Vacuum connections (2-way male parallel faston connectors, 6.3x0.8 – spacing 6.5mm)
Ref.
Description
Controller
in/out
V ref.
I max.
Connected to
VA+
Vacuum system power
out
10-24V
30A
M2+
VA-
Vacuum system power supply -
out
0V
30A
M2-
Figure 21: