49
Service Manual – SC500
04 - Control System
Shop Measurements
The following tables contain some “real world” shop voltage measurements to help you recognize what
“normal” looks like All voltage values were measured with the black (Negative) voltmeter lead connected to
the main battery negative unless otherwise specified.
Shop Measurements - Main machine controller (EB1)
Battery volts at battery, key on = 25 03V
Power Supply
Figure 33:
PIN
Color
Description
Measured
Comments
B+
Red
Main machine controller power
24.5v
Vacuum on
B-
Black
Main machine controller power supply -
0.035vV
Vacuum on