40 - Recovery System
Troubleshooting
Trouble
Possible Causes
Remedy
The vacuum motor will not turn
on
Wiring between Main machine controller (EB1)
and vacuum motor (M2) damaged
Repair
User interface controller (EB3) faulty
Replace
Vacuum motor faulty
Check the amperage
Suction of dirty water is
insufficient or non-existent
Activation of automatic float shut-off
Drain the recovery tank
Debris collection filter dirty
Clean
Vacuum grid with automatic float shut-off dirty
Clean
Tank cover not correctly positioned
Adjust
Tank cover seal damaged or not working
correctly
Clean or replace
Vacuum motor container dirty
Clean
Vacuum seals damaged or not working
correctly
Repair or replace