131
Service Manual – SC500
30 - Solution System
Trouble
Possible Causes
Remedy
The EcoFlex system will not
activate and the LED does not
come on
User interface controller (EB3) faulty
Replace
The Main machine controller (EB1) has not
been set for operation with the EcoFlex
system
If present, remove the
jumper (J6) (Figure 10)
on the rear of the Main
machine controller (EB1)
The symbol
is
displayed when the solution tank
is empty
Humid fouling inside the solution tank
Washing the solution tank
with clean water
Presence of water between the water level
sensor and the outer wall of the solution tank
Dry the area
Water level sensor broken
Replace the sensor
The symbol
is
displayed when the solution tank
is full
Excessive distance between the water level
sensor and the wall of the solution tank
Check the proper installation
of the sensor
Discontinued wiring harness
Check the wiring harness
between the sensor and
the Main machine controller
(EB1)
Water level sensor broken
Replace the sensor
Figure 10: