144
Service Manual – SC500
34 - Scrub System, Disc
Troubleshooting
Trouble
Possible Causes
Remedy
The brush does not clean
properly
The brush is excessively worn
Replace
The brush does not turn
See the chapter Control
System, Main machine
controller (EB1) Error Codes
Brush motor fuse (F4) broken
Replace
Brush motor carbon brushes worn
Replace
Presence of bulky debris or string around the
brush or between the brush and attachment
flange
Remove the brush and clean
it
Faulty brush motor
Repair or replace
Wiring damaged
Repair
It is not possible to raise/lower
the brush
See the chapter Control
System, Main machine
controller (EB1) Error Codes
Deck raising/lowering actuator (M5) broken
Replace
Break in actuator wiring
Check the connections
according to the instructions
in the Electrical System
chapter, Troubleshooting
paragraph
Main machine controller (EB1) damaged
Replace
The brush disengagement
system does not work
Main machine controller (EB1) faulty
Replace