www.usmotors.com
6
ID300/302 Integrated Motor Drive |
Start Up Tips for the ID300/302
1.4 Application-Related 0 Menu
The first 9 parameters of
0 Menu
are most likely application-related features that may need configured
to match the application. Refer to the
0 Menu
parameter list beginning on
page 38
.
• Direction of Rotation – Unlike a regular 3 phase motor, the direction of the ID300/302 unit does
not change by swapping any two of the 3 input power leads. The ID300/302 controller is prewired
to the motor and negates this approach for reversal of direction. Instead, Parameter 8 of 0 Menu
(Force Rev Direction) can be changed from a “0” (OFF) to a “1” (ON) to change the direction of
the motor’s rotation.
• Starting from Last Set Point – The ID300/302 unit is programmed to start from the last
programmed set point, instead of 0 RPM (requiring the entry of a set point every time the unit is
started). If this operation does not match the application, this feature can be change by resetting
Parameter 9 in the 0 Menu
. Use the keypad to access Parameter 9 and change the value from
a “1” to a “0”. This will clear the set point. In this mode, the set point is cleared when the unit is
turned off and will require the set point to be entered when the unit is restarted.
1.5 Fault Condition Reset
Reset the ID300 from a Fault Condition
– If the ID300/302 is using the RTC Keypad for control, any
fault condition will be shown in the display. The cause of the fault and possible corrective action can
be found in Section 6 of the manual beginning on
page 41
. Once the cause is corrected and the motor
rotation has stopped, press the Red button on the RTC Keypad to clear the fault.
If the keypad is the being used to control the
ID300/302 unit, the main electrical power can be
removed for 25 seconds and then reapplied to clear
the fault. An optional method is to open and then
close
Terminal 8
. Refer to Section 4.2 on
page 23
.
1.6 Using the Keypad
Programming and Saving Parameters
– For ease of use, the drive parameters most likely to need
changing are in the
0 Menu
. If there is a need for other parameters to be changed, the menus can be
accessed using the keypad.
This manual provides a detailed explanation of programming the ID300/302 unit and saving the
parameters. Refer to Section 5.1 on
page 34
. Below is a simplified procedure.