www.usmotors.com
ID300/302 Integrated Motor Drive |
Connections
29
4.6.1 Terminal Characteristics
Refer to Section 4.6 on
page 28
for proper isolation of cables.
1
+10V
Size 3 Drive
Function
Supply for external analog devices
Nominal Voltage
10.2 V
Voltage Tolerance
± 3%
Max Output Current
5mA
2
ADI1
Analog or digital input 1
4
ADI2
Analog or digital input 2
AD11 Default Function
10.2 V
AD12 Default Function
± 3%
Type of Input
5mA
Resolution
Sample Rate
Operating in Voltage Mode
Full Scale Voltage Range
0 V to ± 3%
Max Offset
± 30 mV
Absolute Max Voltage Range
-18 V to +30 V relative to 0 V
Input Resistance
100 kΩ
Operating in Current Mode
Current Range
0 to 20 mA ± 5 %
Maximum Offset
250 μA
Load Impedance
165 kΩ
Operating in Digital Mode
Impedance
6.8 kΩ
Input Threshold
10 V ± 0.8 V (IEC 61131-2)
Operating in Thermistor Mode (ADI2 Only)
Voltage Range
± 10 V
Input Threshold
> 3.3 kΩ
Reset Threshold
< 1.8 kΩ
Bias for DIN44081 (PTC), PT1000, PT2000, etc.
3
0V
Function
Common connection for all external devices