TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
20
|
www.hysecurity.com Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 MX4685 Rev. A ©2019
1. Open the actuator mechanical release, remove two Torx 25 screws, and lift off cover.
2. Remove plastic cap covering the two adjustment wheels (IMAGE 10-1).
3. Press the CLOSE button on the control board. The gate should close until it hits the CLOSE limit switch
(LED = RED).
4. If the CLOSE limit is not acceptable (gate closed too far or not enough), open the gate partially and
turn the RETRACT Adjustment Wheel a few revolutions in “retract more” or “retract less” direction as
needed, then press CLOSE button on the Control Board again to check.
5. Check gate and repeat Steps 4-5 as necessary until CLOSE limit is acceptable.
6. Press the OPEN button on control board. The gate should open until it hits the OPEN limit switch
(LED = GREEN).
7. If the OPEN limit is not acceptable (gate open too far or not open all the way), close the gate partially
and then turn the EXTEND Adjustment Wheel a few revolutions in “extend more” or “extend less”
direction and press OPEN button on the Control Board again to check.
8. Check gate and repeat Steps 7-8 as necessary until OPEN limit is acceptable.
9.
When finished, replace plastic cap on switches, affix actuator cover with two screws, engage mechanical
release, and lock.
10B
SETTING ACTUATOR FINE LIMITS: PUSH-TO-OPEN
EXTEND
WHEEL
RETRACT
WHEEL
RETRACT LESS
RETRACT LESS
RETRACT MORE
RETRACT MORE
RETRACT
CAM MOVEMENT
EXTEND
CAM MOVEMENT
EXTEND MORE
EXTEND MORE
EXTEND LESS
EXTEND LESS
Remove rubber cap
to expose wheels
IMAGE 10-1:
TITANL1
ACTUATOR LIMIT SWITCH LOCATIONS & FUNCTIONS
IMPORTANT!
The actuator key MUST be left with the customer. The key is necessary if the gate must be manually
opened in the event of loss of power.