TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
MX4685 REV. A ©2019 Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 www.hysecurity.com |
13
7
MANUALLY SET GATE OPEN/CLOSE LIMITS
To mechanically “teach” the actuator the rough open and close limits, ensure the machanical release is still
open on the actuator, then move the gate manually as follows:
1. Close gate(s) all the way (IMAGE 7-1A) to desired close limit position.
2. Open gate(s) all the way (IMAGE 7-1B) to desired open limit position.
3. Place gates in mid position (IMAGE 7-1C).
4. CLOSE mechanical release of actuator, but do not lock it yet.
IMPORTANT!
If done carefully, manually setting the gate limits may not require further adjustment. Do
not push the gate past the desired limits open or close, or they must be re-adjusted per fine adjustment
INSTRUCTION 10A or 10B in this manual.
A
B
C
IMAGE 7-1:
MANUAL SETTING OF CLOSE/OPEN LIMITS
4.1 MANUALLY SET GATE OPEN/CLOSE LIMITS