TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
12
|
www.hysecurity.com Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 MX4685 Rev. A ©2019
6
OPEN MECHANICAL RELEASE
1. Lift up the rubber key cap (IMAGE 6-1A).
2. Insert key and turn 90° clockwise (IMAGE 6-1B).
3. Lift up the mechanical release (IMAGE 6-1C).
4. After mechanical release is opened, the actuator arm should now be freely extended and retracted
manually.
NOTE:
If manual extension is not possible, the actuator must be partially extended using the motor once
the actuator is powered by the control board.
To extend actuator using the motor, close the mechanical release and momentarily press the OPEN Button
(Push-To-Open) or CLOSE Button (Pull-To-Open) to extend the actuator beyond it’s fully retracted state,
then press the STOP Button. Open the mechanical release again and manual extention should be possible.
A
B
C
IMAGE 6-1:
OPEN ACTUATOR MECHANICAL RELEASE
IMPORTANT!
The actuator key MUST be left with the customer. The key is necessary if the gate must be
manually opened in the event of loss of power.