TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
MX4685 REV. A ©2019 Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 www.hysecurity.com |
11
1. Weld the gate bracket to the gate supporting structure (IMAGE 5-1) or use supplied 3/8” bolts
and nuts from kit (IMAGE 5-2).
2.
If welding is not possible, drill two holes to match bracket mounting holes and affix with two
3/8”x2.5” screws and 3/8” nuts included in the bolt kit (IMAGE 5-2).
IMAGE 5-1:
GATE BRACKET WELDED TO GATE
IMAGE 5-2:
GATE BRACKET AND HARDWARE (BLACK BRACKET SHOWN)
5
AFFIX GATE BRACKET TO GATE
GATE BRACKET
3/8”x2.5”
HEX BOLT (x2)
WELD
3/8” NUT (x2)
1/2”
GATE BRACKET
CENTERLINE
ACTUATOR
ARM
1/2” FROM TOP
SURFACE OF PIVOT
ARM TO CENTERLINE. SEE
INSTRUCTION 1A & 1B.
IMPORTANT!
Ensure bracket centerline is 1/2” above the top of the pivot arm.
GATE BRACKET
IMPORTANT!
Use a bubble level to assure after mounting that actuator is level and plumb.
CAUTION!
NEVER WELD PARTS TO THE GATE OR POSTS WHEN THE CONTROL BOARD IS
POWERED TO AVOID IRREPAIRABLE DAMAGE TO THE CIRCUIT BOARD!
NOTE:
Attach gate bracklet only to
structural supports. If unsure of
exact bracket location, tack weld
or clamp until gate can be tested.