TITAN 912L Actuator
INSTALLATION REFERENCE MANUAL
6
|
www.hysecurity.com Nice/HySecurity, 6705 S 209th St, Ste 101, Kent, WA 98032 - TF: 800-321-9947 MX4685 Rev. A ©2019
IMAGE 1B-1:
"PUSH TO OPEN" PIVOT ARM INSTALLATION
1B
1. Securely mount the pivot arm to the hinge post (IMAGE 1B-1).
2. If necessary, cut pivot arm for correct placement of the actuator
mounting hole. Measurements are taken from the center of pivot of
the gate hinge.
3. It is strongly recommended to weld the pivot arm to the metal post.
INSTALL PIVOT ARM TO GATE: PUSH-TO-OPEN
CAUTION!
NEVER WELD PARTS TO THE GATE OR POSTS WHEN THE CONTROL BOARD IS
POWERED TO AVOID IRREPAIRABLE DAMAGE TO THE CIRCUIT BOARD!
TOP VIEW
6”
6”
11”
11”
PIVOT ARM
PIVOT ARM
PIVOT ARM
1/2”
HINGE POST
CENTER OF HINGE
HINGE POST
HINGE POST
CENTER LINE OF
ATTACHMENT POINT
FOR GATE BRACKET
CENTER OF HINGE
GATE CLOSED
DIRECTION OF OPENING
LEFT SIDE VERTICAL VIEW
NOTE:
Welding is much preferred
but Nice offers an optional bolt-
on pivot arm (P/N 446) for when
welding is not possible.