background image

Installation and Owner's Manual

Access Control Systems

www.calimetco.com

9949 Hayward Way  South El Monte, CA, 91733 

Tel: (626) 452-9009

Ver 3.0 / 2022-03-18

Swing Gate Operator 

CM6

CM6-ACFP  

CM6-DCFP

Summary of Contents for CM6

Page 1: ...Installation and Owner s Manual Access Control Systems www calimetco com 9949 Hayward Way South El Monte CA 91733 Tel 626 452 9009 Ver 3 0 2022 03 18 Swing Gate Operator CM6 CM6 ACFP CM6 DCFP...

Page 2: ...Install Warning Signs 19 After installation 20 Dual Gate Setup 21 Emergency Release 22 Dip Switch Features 23 Circuit Board Layout 24 25 Remote Controls 26 Exit Loops 27 28 Accessory Wiring 29 Locks...

Page 3: ...0 Amp Fuse 24V DC 15 Amp 16 5 x 20 x 24 L x W x H Swing Residential Commercial 1000 lbs 18 Feet 4 F to 140 F Approximately 20 sec for 90 opening Continuous Inherent Reverse Sensor System Type A Photoe...

Page 4: ...t re test the gate operator Failure to maintain the gate operator properly can increase the risk of injury or death Use the emergency release only when the gate is not moving Keep the gate properly ma...

Page 5: ...using Slide Gates Primary Device A Secondary Device one required B1 B2 D Swing Gates Primary Device A C Secondary Device one required A B1 B2 C D Class III Industrial Locations Limited Access Vehicula...

Page 6: ...with the gate while operating the controls Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line o...

Page 7: ...gate during the entire path of travel of the vehicular gate The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator t...

Page 8: ...uthorized use of the gate Vehicular gates should be constructed and installed in accordance with the ASTM F2200 construction standards Electricity The CM6 is powered by 110V 120V AC power If you have...

Page 9: ...rt of the swivel arm D Length of D E 60 The length of D is 60 of E Arm should be 90 from gate when open and straight when closed Distance from the swivel arm nut to the center of the gate bracket Note...

Page 10: ...onduit 3 Pour the concrete pad 4 Use 4 wedge anchors 1 2 to secure the gate operator to the concrete Figure A Above Ground 4 Below Ground Underground depth may vary due to local building codes Reinfor...

Page 11: ...2 20 11 5 2 Install the swivel arm in accordance to the measurements below Compact Installation 31 5 Install using compact installation ONLY when the space between the OPEN gate and wall is between 2...

Page 12: ...igure A A DO NOT allow the arm to touch the gate operator s hood when the gate is in the open position Figure 8 Swivel arm is incorrectly bent Swivel arm must be straight Swivel Arm Positioning Tips 1...

Page 13: ...u re satisfied with testing the arm in the full open and closed positions weld the following 1 Short arm to gate opener metal bar 2 Gate bracket to gate 3 Gate bracket to long arm Step 3 Weld the Door...

Page 14: ...onnect the white wire to the white wire NEUTRAL using a wire nut 5 Connect the black wire to the black wire HOT LINE using a wire nut 6 All operators MUST be properly grounded in order to prevent an e...

Page 15: ...tch 6 Figure A on the bottom of the gate operator circuit board controls the open direction ON opens to the right OFF opens to the left Clockwise Opens to the right Set dip switch 6 to ON Counter Cloc...

Page 16: ...lector to the opposite side Make sure the alignment laser hits inside the circle of the reflector Figure A Figure B 6 Press the orange button on the photocell sensor to turn off the alignment laser Im...

Page 17: ...tocell sensor Outside Property Swing Gate Swing Gate Inside Property Photocell sensor Reflector Secondary Photocell Sensor Wiring Use the same green terminal block input as your primary photocell sens...

Page 18: ...se close distance 2 If gate opens to the left counter clockwise The top limit cam controls the close limit Turn the top limit cam counter clockwise to increase close distance Turn the top limit cam cl...

Page 19: ...n Right Clockwise More Force required to stop the gate Recommended for heavier long gates WARNING Never increase force beyond the minimum amount required to move the gate Too much force may seriously...

Page 20: ...be installed directly on the gate or a nearby wall or post Use screws not supplied to install the warning signs WARNING KEEP CLEAR Gate may move at any time without prior warning Do not let children...

Page 21: ...rator Dual Gate Installation For double gates visit the Dual Gate Setup page for more installation instructions HomeLink Most modern cars come with a feature called Homelink that lets you open your ga...

Page 22: ...oard Figure 2 Use a flathead screwdriver to release the 2 locks on the top of the green terminal 5 Using the electrical wire connect the DATA on the primary gate opener to the DATA on the secondary ga...

Page 23: ...n finished step on the pedal and move it back to the top left Figure B Figure C Emergency Release Right side The emergency release is pressed down allowing you to manually push open the gate Figure B...

Page 24: ...gate operator only set the 5 SLAVE switch to ON If single gate installation set to OFF Gate Open Direction set the direction of which the gate opens when viewed from inside the property Left or Right...

Page 25: ...er Knob 6 Auto Close Timer Knob 7 Open and Close ERD Knob 8 Open Close Stop Reset Buttons 9 Plug in Loop Detetcor Input 10 Electric Lock Input 11 Limit Switch Inputs 12 Loop Detectors Wire Input 13 Co...

Page 26: ...lectric Lock Input 11 Loop Wire for Loop Detectors 12 Open Close Limit Relay 13 Loop Detector Wire Relay Inputs 14 Common Global Input 15 Strobe Light Relay 16 Alarm Relay 17 Master Slave Dual Gate Re...

Page 27: ...his gate operator can add up to 50 different remote controls To add more than 50 remote controls add a receiver which can add up to 100 additional remote controls Calimet remote controls use 418 MHz f...

Page 28: ...exit loop is a device that opens the gate automatically when a car approaches the gate A reverse loop is a loop that reverses the direction of the gate if a car drives over it It will also hold a gat...

Page 29: ...installed in the brackets below figure A The loop wires are installed in the LOOPDETECTOR Relay See the loop detector instruction manual for more installation instructions For other brand exit loops...

Page 30: ...ing the gate operator to power the accessory use 24 VDC and the 24V COM input Figure A Exit Loop Terminals Located on the right side of the circuit board Figure B Relay Terminals Located on the outsid...

Page 31: ...glock Normal Open N O Exit Loop Normal Close N C CL Push To Exit Button Normal Open N O Exit Loop Normal Close N C CL If using the gate operator to power the accessory use 24 VDC and the 24V COM input...

Page 32: ...res electricity Keypad For the Calimet CM9 535 Wireless keypad follow the separate keypad instruction manual for installation details For wired and non calimet brand keypads use a 20 gauge stranded el...

Page 33: ...erator Model Solar Compatibility CM6 ACFP not solar compatible CM6 DCFP solar ready CM6 ACFP Not battery compatible CM6 DCFP Included already installed Solar Panel Accessories Battery 24V Batteries ar...

Page 34: ...Name CL Status Light ON when CLOSE input is activated PED SW SAFETY PHANTOM EXITLOOP LIMIT1 LIMIT2 RADIO RESET POWER B L POWER M S LINK TIMER OPENING CLOSING MON FAULT MON OPEN MON CLOSE ON when Stand...

Page 35: ...l and move it to the upper left E Replace circuit board A No Power B Remote control has no battery C Gate is damaged misaligned or obstructed D Foot pedal is set to manual release E Circuit board Malf...

Page 36: ...pressing the remote control and the study button until the flashing light turns solid about 2 seconds B Downgrade sensitivity on the loop detector A Radio Frequency Interference from another nearby ga...

Page 37: ...o resistance 2 month Electrical 1 year Check wiring connections to make sure none are loose or damaged Check all gate operator accessories including remotes loop detectors keypad etc to make sure they...

Page 38: ...be sent to the warrantor at the consumer s expense to CALIMET CO INC 9949 HAYWARD WAY SOUTHE EL MONTE CA 91733 The warrantor will return the repaired or replaced unit to the customer at the consumer s...

Page 39: ...38 Notes Date Installed Model Number Serial Number Installer Name Installer Company Installer Address Installer Contact NOTES...

Page 40: ...9949 Hayward Way South El Monte CA 91733 Tel 626 452 9009 Alternate 626 482 3066 Fax 626 452 9010 Email info calimetco com www calimetco com...

Reviews: