![background image](http://html1.mh-extra.com/html/calimet/cm6/cm6_installation-and-owners-manual_3445000037.webp)
1 month
Place your hand over the photoscell sensor infrared
beam when the gate is closing. The gate must stop
and reverse.
Two signs should be installed. One is visible to
people on the outside of the gate, and one is visible
to people on the inside of the gate.
1 month
Turn off power and step down on the foot pedal
to move it to the right. Manually push the gate
to ensure that it can fully open and close.
2 months
Step on foot pedal and move it to the right.
Manually push the gate with your hands. Gate
should move freely and easily with little to no
resistance.
2 month
Electrical
1 year
Check wiring connections to make sure none are
loose or damaged
Check all gate operator accessories including
remotes, loop detectors, keypad, etc. to make sure
they are all operating properly.
1 year
Battery
Check to make sure the anchors are not loose or
damaged.
Replace battery (DCFP models only)
4 years
Chassis Sleeve
Anchors
1 year
Gate
Photocell Sensor
check
Warning Signs
Emergency Release
Free Movement
Check
Force
Accessories
6 months
Gate should reverse when it comes in contact
with object. Test both open and close ERD force.
Maintenance
36
Description
Inspect swivel arm, hinges, posts, and other for
wear, damage or misalignment. Lubricate if
necessary. There should be no squeaking.
Check every:
1 month
Task