A second photocell sensor can be installed inside the gate to monitor the OPEN cycle.
This photocell sensor goes inside your property, past the gate's fully open position. If the photocell
sensor's cable isn't long enough you will need to extend (splice) the wires by joining them with
another 20-22 AWG wire for the secondary photocell sensor to be able to reach the gate operator
input.
Reflector
Photocell sensor
Outside Property
Swing Gate
Swing Gate
Inside Property
Photocell sensor
Reflector
Secondary Photocell Sensor Wiring
Use the same green terminal block input as your primary
photocell sensor. Each input can have more than 1 wire
inserted.
Differnet model photocell sensors contain 3 or 4 wires.
Depending on how many your photocell sensor contains, follow
the wiring diagram below.
4 Wires:
Red/Brown > MON_24VDC
Blue and White > COMMON
Black > MON_OPEN
3 Wires:
Red/Brown > MON_24VDC
Blue > COMMON
Gray > MON_OPEN
MON-24VDC
COMMON
MON-OPEN
MON-CLOSE
Installing a secondary Photocell Sensor (Optional)