This parameter can be set with a value from 0 to 64,000 (manoeuvres); the factory setting is 1500 (manoeuvres). This function
enables programming of a reference limit, over which automation maintenance is required. To program the threshold, select the
required value by means of keys
p
and
q
Press “
OK
” to memorise.
This function enables the user to view the number of manoeuvres performed by an automation since the last maintenance pro-
cedure on the latter.
This parameter type is ON / OFF; the factory setting is “OFF”. This function enables deletion of the “partial count” value; this is
required after performing maintenance on the automation.
To cancel, select ON by means of the key
p
and press “
OK
”.
Cancel maintenance
Partial count
Alarm threshold value
MAINTENANCE
PARAMETER
Bluebus
PHOTOCELLS:
FOTO
FOTO II
FOTO 1
FOTO 1 II
FOTO 2
FOTO 2 II
FOTO 3
OPEN FOTO
OPEN FOTO II
COMMANDS:
CMD 1
CMD 2
CMD 3
CMD 4
OTHERS:
GATE
BLOCK AUTOMATION
MEMORY
BUS
STAND-BY
DESCRIPTION
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the photocell is present, the relative operating sta-
tus and the correct memorisation in the control unit.
Indicates whether the control photocell is present, the relative opera -
ting status and the correct memorisation in the control unit.
Indicates whether the control photocell is present, the relative opera -
ting status and the correct memorisation in the control unit.
Indicates whether the control device is present, the relative operating
status and the correct memorisation in the control unit.
Indicates whether the control device is present, the relative operating
status and the correct memorisation in the control unit.
Indicates whether the control device is present, the relative operating
status and the correct memorisation in the control unit.
Indicates whether the control device is present, the relative operating
status and the correct memorisation in the control unit.
Indicates the operating status of the application.
Indicates when the automation is blocked following a “Block” com-
mand.
Indicates a problem regarding the data related to bluebus devices,
memorised in the control unit.
Indicates whether there is a short circuit on the bluebus output.
Indicates when the control unit is in standby status.
This function enables the display of the device type, operating status, and configuration of the devices connected to the Blue-
bus output. These parameters are described in
Table 7
.
TABLE 7
: DIAGNOSTICS of bluebus devices
Diagnostics of bluebus devices