FUNCTION
sca
(= gate open indicator)
gate open
gate closed
maintenance indicator light
courtesy light
suction cup 1
red traffic light
green traffic light
radio channel no.1
DESCRIPTION
The programmed light indicates the operating status of the
control unit.
light off
= application stationary in maximum Closing position;
slow flashing
= application Opening manoeuvre execution
phase;
quick flashing
= application Closing manoeuvre execution
phase;
light permanently on
= application stationary in position oth-
er than maximum closing
Output active 24 Vdc / max 4 W
The programmed light indicates the operating status of the
control unit.
light on
= application in maximum Opening position;
light off
= application in other positions.
Output active 24 Vdc / max 10 W
The programmed light indicates the operating status of the
control unit.
light on
= application in maximum Closing position;
light off
= application in other positions
Output active 24 Vdc / max 10 W
The programmed light indicates the count of manoeuvres
completed and therefore the need (or not) for system mainte-
nance operations.
light on for 2 sec at start of Opening manoeuvre
= number
of manoeuvres less than 80%;
light flashing during execution of entire manoeuvre
= num-
ber of manoeuvres between 80 and 100%;
light always flashing
= number of manoeuvres over 100%.
Output active 24 Vdc / max 4 W
This function type is ON/OFF.
Important
– For safety reasons,
as the light is not controlled by a timer, use of an adequate light
is recommended able to withstand the heat of the light emitted.
Output active 24 Vdc / max 4 W
With this function programmed, the suction cup is activated
when the application is in the maximum Closing position.
Note
– The suction cup is disabled in all other situations.
Output active 24 Vdc / max 4 W
This function indicates activity of the application during the
phases of a Closing manoeuvre.
slow flashing
= execution of Closing manoeuvre;
light permanently on
= application in maximum Closing
position;
light off
= application in other positions
Output active 24 Vdc / max 4 W
This function indicates activity of the application during the
phases of an Opening manoeuvre.
slow flashing
= execution of Opening manoeuvre;
light permanently on
= application in maximum Opening
position;
light off
= application in other positions
Output active 24 Vdc / max 4 W
If this radio channel is set for the configuration of output 1
(flash), this channel is activated when a command is sent with
the transmitter. It is useful if installing external devices (for
example, an auxiliary light) in the same system to be controlled
In this output the user can select one of the functions specified in
Table 4
.
TABLE 4
: OUTPUT CONFIGURATION
Output 3 (sca)