function enables programming of the flashing time which indicates the imminent start of an Opening manoeuvre and is associat-
ed with the “preflash” function. Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
•
closing time
This parameter is expressed in seconds and can be set with a value from 0 to 10 seconds; the factory setting is 3 seconds. The
function enables programming of the flashing time which indicates the imminent start of a Closing manoeuvre and is associated
with the “preflash” function. Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
•
active
This parameter type is ON / OFF; the factory setting is “OFF”. When this function is set to “ON”, automation power consump-
tion can be reduced. Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
•
mode
The function has 3 operating modes:
❏
safety
– when this mode is set, at the end of a manoeuvre and when the standby time has elapsed (parameter program-
mable in the function “wait time”), the control unit switches off the transmitters of the Bluebus photocells and all leds, with the
exception of the Bluebus led, which flashes at a slower interval.
Note
– When the control unit receives a command, it auto-
matically restores normal operation of the automation, and no longer in energy saving mode.
❏
bluebus
– when this mode is set, at the end of a manoeuvre and when the standby time has elapsed, the control unit
switches off the Bluebus output (devices) and all leds, with the exception of the Bluebus led, which flashes at a slower inter-
val.
Note
– When the control unit receives a command, it automatically restores normal operation of the automation, and no
longer in energy saving mode.
❏
all
– when this mode is set, at the end of a manoeuvre and when the standby time has elapsed, the control unit switches
off the Bluebus output (devices), some internal circuits and all leds, with the exception of the Bluebus led, which flashes at a
slower interval.
Note
– When the control unit receives a command, it automatically restores normal operation of the automa-
tion, and no longer in energy saving mode.
Mode programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
•
wait time
This parameter is expressed in seconds and can be set with a value from 0 to 250 seconds; the factory setting is 60 seconds. The
function enables programming of the time which must pass between the end of a manoeuvre and the start of the “standby” func-
tion, if the latter is active (ON). Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
This parameter type is ON / OFF; the factory setting is “OFF”. This function enables automation operation to be disabled, by set-
ting the value to “ON”. In this case no type of command is acknowledged or performed, with the exception of “High priority
step-step”, “Release”, “Release and close” and “Release and open”. Parameter programming: select the required value by
means of keys
p
and
q
, then press “
OK
”.
This parameter type is ON / OFF; the factory setting is “OFF”. This function disables operation of the keys present on the con-
trol unit. Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
This parameter type is ON / OFF; the factory setting is “OFF” . When this function is activated (ON) a brief closing manoeuvre is
activated before the opening manoeuvre starts (starting from the gate closed position) to facilitate release of the electric lock.
Parameter programming: select the required value by means of keys
p
and
q
, then press “
OK
”.
This parameter is expressed in milliseconds (ms) and can be set with a value from 0 to 2.5 seconds; the factory setting is 1.3
seconds. This function enables programming of the duration of the “brief inversion” of the motors; this is implemented after a
“Halt” command is sent to the control unit. Parameter programming: select the required value by means of keys
p
and
q
, then
press “
OK
”.
This parameter is expressed in milliseconds (ms) and can be set with a value from 0 to 1 seconds; the factory setting is 0 sec-
onds. This function enables programming, for each motor, of the duration of the “brief inversion” at the end of a complete clos-
ing manoeuvre. Discharge programming: select the motor (1 or 2), by means of keys
t
and
u
; then select the required value
using keys
p
and
q
, and press “
OK
” to memorise.
Advanced parameters
This item covers the commands available and associable with
inputs 1-2-3
present on the control unit of an automation. The
commands available for each input are described in
Table 1
; while the command categories and relative operating modes are
described in
Tables 1a
,
1b
,
1c etc
.
Important – For correct operation of the control unit, the command programmed on
an input must be associated with the corresponding command category and lastly the required operating mode.
Stand-by
COMMAND configuration
Release stroke
Key lock
Operator block
Brief inversion value
Close discharge