executes the Closing manoeuvre.
Input configured as normally open.
When this command is sent, the control unit
activates the application to complete the next
manoeuvre following the previous one (or still in
progress) according to the sequence of ma -
noeuvres as envisaged in the programmed ope -
rating mode sequence.
Important
– This command is performed even
if the control unit is set with the command “blo -
ck” (see Table 1).
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is rea ched as
set in the function “partial open 2” (Control unit
functions > installation > positions > partial
open 2). The next manoeuvres are per formed
with the set sequence in the programmed
operating mode.
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is reached as
set in the function “partial open 3” (Control unit
functions > installation > positions > partial
open 3). The next manoeuvres are performed
with the set sequence in the programmed ope -
rating mode.
Input configured as normally open.
When this command is sent the control unit
activates the application to complete the Ope -
ning manoeuvre until the position is reached as
set in the function “opening”(Control unit func-
tions > installation > positions > opening). On -
ce the mechanical stops are rea ched, the au -
tomation is blocked.
Input configured as normally open.
When this command is sent, the control unit
activates the application to perform the Closing
manoeuvre until the mechanical closing stops
are reached. Once the mechanical stops are
reached, the automation is blocked.
Input configured as normally open.
When this command is sent, the control unit is
blocked and does not perform any type of
com mand, with the exception of “High priority
step-step”, “Release”, “Release and close” and
“Release and open”.
Input configured as normally open.
When this command is sent, the control unit is
released restoring normal operating status (all
commands sent can be performed).
Input configured as normally open.
This command enables activation of the cour-
tesy light, programmable on Output 1, 2 and 3.
The courtesy light remains active for the time
as programmed in the function “courtesy light
time” (Control unit functions > advanced pa -
rameters > output configuration > courtesy li -
ght time)
Note
– When the courtesy light is
High priority step step
Partial open 2
Partial open 3
Open and block
Close and block
Block
Release
Timed Courtesy light
Step step
program the required operating mode, se -
lecting in
Table 1-A
(
command configu-
ra tion”
>
“step step”
> operating mode...)
Partial open
program the required operating mode,
selecting in
Table 1-B
(
command con-
figuration”
>
“partial open”
> operating
mode...
Partial open
program the required operating mode,
selecting in
Table 1-B
(
command con-
figuration”
>
“partial open”
> operating
mode...
Opening
program the required operating mode, se -
lecting in
Table 1-C
(
command configu-
ration”
>
“opening”
> operating mode...)
Closing
program the required operating mode, se -
lecting in
Table 1-D
(
command configu-
ration”
>
“closing”
> operating mode...)