Apartment block 2 step step
Hold-to-run
Industrial mode
This executes the sequence “
Partial open - Partial open
”
through to the position programmed in the “Partial open” func-
tion; if another command is sent after reaching this position,
the control unit activates a closing manoeuvre.
Important
- If
the command sent remains active for more than 2 seconds,
the control unit activates a stop command.
The “Partial Open” or “Closing” manoeuvre is executed exclu-
sively if the hold-to-run command is used.
This executes the sequence “
open in semi-automatic –
close in hold-to-run
”.
OPERATING MODE
Open - Stop - Open
Apartment block 1
Apartment block 2
Hold-to-run Open
Industrial mode
DESCRIPTION
Operating mode set in factory (Input 2 - “open” com-
mand).
This executes the above sequence.
This executes the sequence “
open- open
”.
This executes the sequence “
open- open
”.
Important
- If the
command sent remains active for more than 2 seconds, the
control unit activates a stop command.
The Opening manoeuvre is executed exclusively if the sent
command persists (hold-to-run).
This executes the sequence “open in semi-automatic – close
in hold-to-run”.
In this command category the user can select one of the operating modes specified in
Table 1-C.
TABLE 1-C
: COMMAND CONFIGURATION
Open
OPERATING MODE
Close - stop - close
Apartment block 1 close
Apartment block 2 close
Hold-to-run close
Industrial mode
DESCRIPTION
Operating mode set in factory (Input 3 - “close” com-
mand).
This executes the above sequence.
This executes the sequence “
close-close
”.
This executes the sequence “close-close”.
Important
– When
sending a command, if the latter remains active for more than
2 seconds, the control unit activates a Stop.
The Closing manoeuvre is executed exclusively if the sent
com mand persists (hold-to-run).
This executes the sequence “
open in semi-automatic – clo -
se in hold-to-run
”.
In this command category the user can select one of the operating modes specified in
Table 1-D
.
TABLE 1-D
: COMMAND CONFIGURATION
Close
OPERATING MODE
Halt
Halt and brief inversion
DESCRIPTION
When this type of function is set, when the control unit re -
ceives the command, it stops the Opening manoeuvre in
progress immediately.
Operating mode set in factory.
When the control unit re -
ceives the command, it stops the Opening manoeuvre in pro -
gress immediately and activates the application to perform a
brief inversion in the opposite direction (Closing).
In this command category the user can select one of the operating modes specified in
Table 1-E
.
TABLE 1-E
: COMMAND CONFIGURATION
Halt on opening