background image

32

27 - EMERGENCY VEHICLE ACCESS

27.1 

The automatic vehicular gate system must be designed to allow access 
to emergency vehicles under different operating conditions.

27.2

  During normal powered operation, emergency vehicles access the gate 

by use of the emergency vehicle access device installed on your gate 
system. The type of device that is used in your community is dependent 
on your city codes. These devices may include (but are not limited to) 
Fire Department lock boxes, Click-2-Enter radio receivers, strobe light 
sensors, siren sensors, etc.

27.3

  Check with your installer to determine if your gate system is equipped 

with a back-up power system. In the event of a primary (AC) power 
failure and a back-up system (DC) power failure (low charged or dead 
batteries for example), the system must have a release system to 
allow the gate to be manually operated. The release device must be 
accessible from either side of the gate and must be present so that 
emergency personnel can gain access through the gate under this 
condition.

27.4 

This operator is equipped with a manual release system that will 
allow the gate to be pushed open in the event of a power outage or 
equipment failure.

 

NOTE:

 Never attempt to manually push open any gate with an operator 

attached to it until you have verified that power to the operator has been 

shut-off.

27.6 

The automatic vehicular gate system must be designed to allow access 
to emergency vehicles under different operating conditions.

27.7

  In the event of a power failure, the emergency vehicle access device 

may not be functional because the gate operator is un-powered. NOTE: 
DC powered back-up systems are optional and your gate system may 
or may not be equipped with one. Check with your installer to determine 
if your gate system is equipped with a back-up power system.

27.8

  The FAIL-SAFE manual operation system is the most reliable and safest 

method for placing an automated gate in manual operation and is the 
preferred method of emergency gate operation under worse case 
conditions by many Fire Chiefs and Building Inspectors and is typically 
used in CLASS I and CLASS II applications. 

27.9

  For manual fail-safe gate operation, turn power to the operator OFF. If a 

backup power system is in use, be sure that this power is turned OFF 
also. Once power is OFF, the gate can be manually operated, by using 
the MANUAL RELEASE handle under the top cover. 

28 - GLOSSARY

BLOCK

- Ceases all operator function except HIGH PRIORITY inputs. 

COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR-

CLASS II

 - A vehicular gate operator (or system) intended for use in a 

commercial location or building such as a multi-family housing unit (five 
or more single family units), hotels, garages, retail store, or other building 
servicing the general public.

ENTRAPMENT

 - The condition when an object is caught or held in a position 

that increases the risk of injury.

FORCE STATIC

 - Constant load threshold for sensitivity setting.

FORCE DYNAMIC

 - Impact sensitivity setting.

GATE

 - A moving barrier such as a swinging, sliding, raising, lowering, or the 

like, barrier, that is a stand-alone passage barrier or is that portion of a wall 
or fence system that controls entrance and/or egress by persons or vehicles 

and completes the perimeter of a defined area.

(STEP H) HIGH PRIORITY

 - Step by step control.

INHERENT ENTRAPMENT SENSOR SYSTEM

 - An automatic sensor 

system which senses entrapment of a solid object and is incorporated as a 
permanent and integral part of the operator.

INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR-

CLASS III 

- A vehicular gate operator (or system) intended for use in an 

industrial location or building such as a factory or loading dock area or other 
locations not intended to service the general public.

RESTRICTED ACCESS VEHICULAR GATE OPERATOR-CLASS IV

 - A 

vehicular gate operator (or system) intended for use in a guarded industrial 
location or building such as an airport security area or other restricted access 
locations not servicing the general public, in which unauthorized access is 
prevented via supervision by security personnel.

RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I 

- A vehicular 

gate operator (or system) intended for use in a home of one-to four single 
family dwelling, or garage or parking area associated therewith.

STEP BY STEP

 - Command that opens-stops-closes-stops the gate with 

each press of the button. 

SYSTEM

 - In the context of these requirements, a system refers to a group of 

interacting devices intended to perform a common function.

UNBLOCK

 - Resumes normal operation after a blocked condition. 

WIRED CONTROL

 - A control implemented in a form of fixed physical 

interconnections between the control, the associated devices, and an 
operator to perform predetermined functions in response to input signals.

WIRELESS CONTROL

 - A control implemented in means other than fixed 

physical interconnections (such as radio waves or infrared beams) between 
the control, the associated devices, and an operator to perform predetermined 
functions in response to input signals.

26 - RE-ASSEMBLING GATE OPERATOR 

1

1

3

2

2

b

a

c

4

Summary of Contents for Apollo 4300SW

Page 1: ...Revision 1 0 0_03 2012 Nice Apollo Swing Gate Opener Vehicular Swing Gate Opener 4300SW 1 2HP 4500SW 1HP...

Page 2: ......

Page 3: ...3 17 2 Fail safe connection 23 17 3 Magnetic lock connection 23 17 4 Guard station connection 23 17 5 Exit and edge inputs wiring diagram 24 17 6 Radio receiver connection third party 24 18 INSPECTION...

Page 4: ...tings need to be made A real time clock calendar enables programming for scheduled weekly or daily events like opening closing or locking the gate Gate opening and closing speed acceleration soft star...

Page 5: ...Drive Electromechanical Gate Length Max up to 16 ft 5 m up to 20 ft 6 m Gate Weight Max 600 lb leaf 272 kg 1 000 lb leaf 272 kg Open Close Time to 90 12 18s adjustable Temperature Rating 4 to 122 F 2...

Page 6: ...nd reliable operation it is essential these components operate together as a system It is the responsibility of the system designer and or installer to ensure any safety or operational issues have bee...

Page 7: ...le family dwellings 2 1 2 Class II Commercial General Access Gate Operator Intended for use in a commercial location or building such as a multi family housing units ve or more single family units hot...

Page 8: ...nt risk Swinging gates shall not open into public access areas 2 6 The gate must be properly installed and work freely in both directions prior to gate operator installation Don t change operator sett...

Page 9: ...vehicle detectors cannot provide protection to pedestrians In some situations photoelectric devices may be used as vehicle detectors but should be wired accordingly 4 Gate Construction and Safety Gate...

Page 10: ...slide gates 4 2 1 1 All weight bearing exposed rollers 8 ft 2 44 m or less above grade shall be guarded or covered 4 2 1 2 All openings shall be designed guarded or screened from the bottom of the ga...

Page 11: ...ll not be less than 16 in 406 mm Exception For a gate that is not in compliance with this provision the de ned area shall be subject to the entrapment protection provisions of UL 325 4 3 5 Class IV ve...

Page 12: ...aces is less than 16 in 406mm Potential entrapment zones are shown below for slide gates but keep in mind there may be other entrapment zones presented by the actual installation and adjacent structur...

Page 13: ...tion provided the gate in the open direction presents no risk of entrapment Slide Gates One sensor in the Open direction and one sensor in the Close direction The gate operator tests for the presence...

Page 14: ...ces s required Accessory Output Connections Power Input Connections Motor Output Connections BlueBus Connection Master Slave Connection Accessory Input Connections Earth Ground 9 4300 4500 PARTS IDENT...

Page 15: ...towed back for safe assembly of the gate operator Storage area for two 12VDC backup batteries for 24 volt motor power Use these holes for attaching I O cables with plastic zip ties Limit Switch 10 SWI...

Page 16: ...ical mounting Drill and insert RedHead 1 2 x 3 1 3 concrete anchors into the concrete sufficient to properly mount the gate opener Mounting position must be a minimum distance of 21 inches distance be...

Page 17: ...3 Steps 1 2 3 8 Adjust the Closed Limit Switch as done for the Open limit loosen the set screw and move the arm for the close limit until the RED light illuminates on the front of the control board se...

Page 18: ...on how to place the NICE 1050 control board into learning mode If the board is not in LEARN MODE press FUNCTION OK SWING OK LIGHT OK AVERAGE HEAVY You are in LEARN MODE if ENTER is flashing For dual...

Page 19: ...ttery is connected backwards a red LED will illuminate below the terminal Main DC Power This terminal block is for incoming 10 32VDC power only Connect wires to the main DC power terminal block Positi...

Page 20: ...and 3 pin and connector into the connection labeled Motor 2 for a dual leaf swing gate installation GREEN ORANGE BLUE YELLOW WHITE DO NOT USE RED BLACK MOTOR 1 4300 4500 ACTUATOR SINGLE MOTOR PULL TO...

Page 21: ...nstallation manual Limits and motor direction MUST be set prior to learning the board 2 Press and hold the OPEN or CLOSE button on the gate controller until the gate is 50 open 3 Press OK to allow the...

Page 22: ...AP Input 26 Dry contact input that can be programmed for an inductive safety loop or photo eye detector Shorting the ENTRAP input 26 to GND while the gate is opening cause the gate to close to the ful...

Page 23: ...specific control of individual gate functions The receiver includes built in programming functions for adding or removing Nice FloR A wireless remote controls to from a gate installation The followin...

Page 24: ...in the system Table 1 Wire Gauges and Maximum Power Circuit Distances 110V AWG 14 12 10 8 6 4 MAX RUN ft 180 280 460 700 1150 1800 Figure 19 GROUNDING WIRE The gate operator should be grounded to a c...

Page 25: ...arallel with the Fire input to release the motor in the event of an emergency entry by the fire department during a power failure Opening the FAIL SAFE contacts allows the gate to be pushed open by ha...

Page 26: ...f the correct type and amperage 18 9 Insufficient clearance between exposed current carrying parts and ground or poor insulation of exposed terminals All exposed connections must be covered prevent ar...

Page 27: ...xed object Figure 26 GENERAL GATE LAYOUT IN GROUND LOOPS Figure 26 GENERAL GATE LAYOUT WITH PHOTO EYES Possible Entrapment Zone Typical Installation Diagram Utilizing Loop Sensors and Photocells Possi...

Page 28: ...s a thru beam device consisting of a transmitter TX and a receiver RX that connects via two 2 wires Polarity of the wiring is not important EPMOBs may be wired in parallel to one another or directly t...

Page 29: ...ct Open Pule or Close Pulse and Press OK 5 Connect 300Hz Monitored Safety Device to In1 16 or NOTES Only one monitored Pulse device may be connected per input at In1 or In2 At least one monitored devi...

Page 30: ...ng Diagram EMX WEL 200 Wireless Edge Receiver Dip Switch Settings determine which relay activates when the associated edge is tripped See WEL 200 manual for instructions for programming receiver trans...

Page 31: ...R CHANGES ARE IMPLEMENTED TO ENSURE PROPER FUNCTIONALITY AND SAFETY 24 BOARD NOMENCLATURE Safety Shadow Entrap Shadow Adjust force settings for gate opening and closing Adjust speed settings for gate...

Page 32: ...ripherals enables the gate operator to discover and integrate accessory devices like Blue BUS access control and safety devices Positions Configures the points in the gate open close and partial cycle...

Page 33: ...ttery All the outputs are switched off and the LED OK blinks to show this standby status of the system Advance Settings The following settings are available for customizing the gate operator as requir...

Page 34: ...perator function except HIGH PRIORITY inputs COMMERCIAL GENERAL ACCESS VEHICULAR GATE OPERATOR CLASS II A vehicular gate operator or system intended for use in a commercial location or building such a...

Page 35: ...have accumulated Every 6 months 30 NICE GATE OPENER TROUBLESHOOTING POSSIBLE SOLUTION Check that power to the operator is turned ON Check terminal block wiring for loose or broken wires Check for 115...

Page 36: ...in each direction Appears when Swing gate operator does not have at least one entrapment sensor programmed and installed for both open and close direction for travel Appears when previously learned n...

Page 37: ...tance 48 std std 40 14 40 1 8 50 std std 37 14 42 1 8 51 1 2 std std 34 14 42 3 4 52 3 4 std std 31 14 42 3 4 54 std std 28 14 42 1 4 57 7 8 std std 13 14 37 1 2 Table 3 Installation layout E A B C D...

Page 38: ...33 TEMPLATE FOR INSTALLATION 3 Chart C A B C D E Ang 53 std std 24 3 4 16 100 53 13 16 std std 12 18 110 50 std std 11 22 120 Chart D A B C D E Distance 32 3 8 23 1 8 25 1 8 25 11 21 Table 4 21 Figure...

Page 39: ...37 34 COMPACT INSTALLATION ARM MEASUREMENTS Figure 32 ARM MEASUREMENTS 21 25 11 32 1 4 25 1 2 23 3 16 5 7 8 15 3 4 1 2 1 3 16 7 7 8 7 1 8 1 2 1 2 1 3 16 7 7 8 7 1 8 1 2 1 2...

Page 40: ...38 35 GATE ARM INSTALLATION Figure 33 CORRECT LAYOUT INCORRECT INSTALLATION Figure 34...

Page 41: ...er clockwise to release the adjustment knob 2 Rotate the knob as shown to increase or decrease the length of the main arm NOTE Do not extend the main arm more than 2 3 Using a 2 5mm or 3 32 hex key tu...

Page 42: ...ondition of the drive motor The gate will then run to the closing limit so that it can properly sense where it is located 13 The control board will then OPEN the gate slowly to establish travel and li...

Page 43: ...to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has instructed the customer i...

Page 44: ......

Page 45: ......

Page 46: ...Contact us Nice 6705 S 209th St Suite 101 Kent WA 98032 2327 Ph 1 253 867 3700 Fax 1 253 867 3702 www hysecurity com www facebook com hsgateoperators...

Reviews: