18
13 - 4300/4500 LIMIT AND MOTOR WIRING
13.2 - 4300/4500 WIRING (PUSH TO OPEN)
4300/4500 limit switch and smart sensor wiring
Connect the Nice
4300/4500
cable to the 5-pin connector as
shown below. These connections enable the Nice 4300/4500
limit switch and smart sensor inputs into the gate controller.
Nice actuator motor wiring
Connect the Nice
4300/4500
actuator motor leads to the
3-pin connector as shown below.
Note:
If the gate moves in the opposite direction from what
is expected, reverse the motor wiring from what is shown.
(Red to Pin 1, Black to Pin 3).
Install the 5 and 3-pin connector into the connection labeled
“Motor 1” on the controller. Install the 5 and 3-pin and
connector into the connection labeled “Motor 2” for a dual
leaf swing gate installation.
13.1 - 4300/4500 WIRING (STANDARD)
4300/4500 limit switch and smart sensor wiring
Connect the Nice
4300/4500
cable to the 5-pin connector as
shown below. These connections enable the Nice 4300/4500
limit switch and smart sensor inputs into the gate controller.
Nice 4300/4500 actuator motor wiring
Connect the Nice
4300/4500
actuator motor leads to the
3-pin connector as shown below.
Note:
If the gate moves in the opposite direction from
what is expected, reverse the motor wiring from what is
shown. (Red to Pin 3, Black to Pin 1).
Install the 5 and 3-pin connector into the connection labeled
“Motor 1” on the controller. Install the 5 and 3-pin and
connector into the connection labeled “Motor 2” for a dual
leaf swing gate installation.
GREEN
ORANGE
BLUE
YELLOW
WHITE
DO NOT USE
RED
BLACK
MOTOR 1
4300/4500 ACTUATOR SINGLE MOTOR - PULL TO OPEN
WHITE: Close Limit
ORANGE: Open Limit
GREEN: Limit Common
YELLOW: Encoder Signal
BLUE: Encoder Power
NOTE: If the gate move
in opposite
direction from
what is expected,
reverse the motor
power lead wiring
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
MOTOR LEADS
GREEN
WHITE
BLUE
YELLOW
ORANGE
DO NOT USE
BLACK
RED
MOTOR 1
4300/4500 ACTUATOR SINGLE MOTOR - PUSH TO OPEN
WHITE: Close Limit
ORANGE: Open Limit
GREEN: Limit Common
YELLOW: Encoder Signal
BLUE: Encoder Power
NOTE: If the gate move
in opposite
direction from
what is expected,
reverse the motor
power lead wiring
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
MOTOR LEADS
WHITE: Close Limit
ORANGE: Open Limit
GREEN: Limit Common
YELLOW: Encoder Signal
BLUE: Encoder Power
MOTOR 1
MOTOR 2
GREEN
WHITE
YELLOW
BLUE
ORANGE
GREEN
BLUE
YELLOW
WHITE
ORANGE
DO NOT USE
4300-4500 ACTUATOR DUAL MOTOR - PUSH TO OPEN
RED
BLACK
BLACK
RED
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
MOTOR LEADS
4300-4500
ACTUATOR
MOTOR LEADS
WHITE: Close Limit
ORANGE: Open Limit
GREEN: Limit Common
YELLOW: Encoder Signal
BLUE: Encoder Power
MOTOR 1
MOTOR 2
GREEN
ORANGE
YELLOW
BLUE
WHITE
GREEN
BLUE
YELLOW
ORANGE
WHITE
DO NOT USE
4300-4500 ACTUATOR DUAL MOTOR - PULL TO OPEN
BLACK
RED
RED
BLACK
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
(with encoder)
4300-4500
ACTUATOR
MOTOR LEADS
4300-4500
ACTUATOR
MOTOR LEADS
Summary of Contents for Apollo 4300SW
Page 2: ......
Page 40: ...38 35 GATE ARM INSTALLATION Figure 33 CORRECT LAYOUT INCORRECT INSTALLATION Figure 34...
Page 44: ......
Page 45: ......