5.5 Command Explanation
FRA5022
5-27
[:SOURce]:SWEep:SPACing[:TYPE] <freq_spacing>
[:SOURce]:SWEep:SPACing[:TYPE]?
Description:
Sets/queries the sweep measurement frequency axis format.
Parameters:
<
freq_spacing
>
frequency axis format, format
<
CRD
>
,
range LINear | LOGarithmic
Settings example:
SWE:SPAC LIN
Response:
<
freq_spacing
>
The response is in short form (LIN
|
LOG).
Query example:
SWE:SPAC?
Response example:
LIN
[:SOURce]:SWEep:SPACing:POINt <freq_points>
[:SOURce]:SWEep:SPACing:POINt?
Description:
Sets/queries the sweep measurement frequency points
(measurement points).
The measurement occurs a number of time specified frequency
point at regular intervals on either linearly (Lin) or
logarithmically (Log) axis between the minimum and the
maximum frequency.
Parameters:
<
freq_points
>
frequency points, format
<
NR1
>
, range 3 to 1000
Settings example:
SWE:SPAC:POIN 1000
Response:
<
freq_points
>
Query example:
SWE:SPAC:POIN?
Response example:
1000
[:SOURce]:SWEep[:LEVel]:MAXimum <freq_max>
[:SOURce]:SWEep[:LEVel]:MAXimum?
Description:
Sets/queries the sweep measurement maximum frequency.
Parameters:
<
freq_max
>
maximum frequency, format
<
NR3
>
,
range 0.11E
-
03 to 100.00E+03 [unit Hz]
Settings example:
SWE:MAX 100kHz
Response:
<
freq_max
>
Query example:
SWE:MAX?
Response example:
100.00E+03
[:SOURce]:SWEep[:LEVel]:MINimum <freq_min>
[:SOURce]:SWEep[:LEVel]:MINimum?
Description:
Sets/queries the sweep measurement minimum frequency.
Parameters:
<
freq_min
>
minimum frequency, format
<
NR3
>
,
range 0.10E
-
3 to 99.999E+03 [unit Hz]
Settings example:
SWE:MIN 0.0001
Response:
<
freq_min
>
Query example:
SWE:MIN?
Response example:
0.10E
-
03
Summary of Contents for FRA5022
Page 1: ...NF Corporation FREQUENCY RESPONSE ANALYZER FRA5022 Instruction Manual...
Page 2: ......
Page 3: ...FREQUENCY RESPONSE ANALYZER FRA5022 Instruction Manual DA00016981 005...
Page 26: ...2 2 Installation FRA5022 2 8 Figure 2 5 Removal of feet...
Page 30: ...FRA5022 2 12...
Page 92: ...5 5 Command Explanation FRA5022 5 14 Query example SRE Response example 128...
Page 119: ...FRA5022 5 41...
Page 131: ...FRA5022 7 8...
Page 141: ......
Page 143: ......
Page 144: ......