5.6 Description of Individual Commands
CA5350
5-13
H
– Key Input
Description: Key Input
Setting:
H14
◀
H15
▶
H16
(Left rotation of knob)
H17
(Right rotation of knob)
H18
▴
H19
▾
H20
EXIT
H21
ENTER
H22
MENU
Remarks:
This will perform the same processes as pressing the front panel keys of
CA5350
. For parameters other than above, it will result in error.
I
– Input select
Description: Input connector select
Setting:
I0
Use the input connector located on the front panel (factory default
settings)
I1
Use the input connector located on the rear panel
Remarks:
Select the current input connectors of
CA5350
.
J
– Self-Check execute
Description: Self-check execute.
Setting:
J0
Perform memory test
J1
Perform memory test and LCD display test
Remarks:
It will perform similar tests as conducted when turning on the power
supply. If error is detected, error message will appear on LCD. Besides,
results of memory test can be queries with
U1
command. For the details
of the test contents, refer to
“3.2 Display at Power “ON” and Initial
Setting
”
.