10. Re-secure the extraction handle retaining bolt. See
Replacing a Unity Storage System controller
11. Replace all cables on the new controller.
Notes:
Be sure to put all cables back into the proper ports. See Step 4 under
If the controller does not automatically start up, select it in Unity and click the
Turn On
button in its
Properties panel at the bottom of the screen.
12. Verify that the new fan is working using the
sensors
command in the command-line interface (CLI). See
Accessing the nxadmin CLI
and
Using the nxadmin CLI’s command-based shell
in the
Nexsan Unity CLI
Reference Guide
.
13. Migrate the resources back to the controller you removed using Unity. See
Moving Cluster Resources
in
the
Nexsan Unity Software User Guide
.
►
To replace a lower layer fan 2 or 3 (Unity 2200 or Unity 2200X):
1. Perform the component identification and controller removal steps under
2. Remove Upper Layer Fan 1, but do not detach it from power (see
on page 43, far left
photograph). Set it aside.
3. If necessary, unscrew the fan bracket from the back of the controller and remove it.
Figure 2-17: Removing the fan bracket
4. Gently lift the fan from its slot.
Figure 2-18: Removing Primary Fan 2 or 3
Chapter 2: Customer Replaceable Units: Class 2
2
Nexsan Unity
49