Power supply units (PSUs)
Unity Storage Systems include redundant power supply units (PSUs). In case one fails, the unit can continue
to operate for a brief period using only the power from the other PSU.
Note
The cooling fans in each PSU operate on separate circuits from the power supply itself. If one PSU fails,
its fans continue to run on power supplied by the other PSU.
CAUTION:
When a failed PSU is removed, ALWAYS replace it as soon as possible. Two functional
PSUs are necessary to maintain proper operation and cooling for the unit.
Identifying failed power supply units (PSUs)
A failed power supply unit (PSU) is indicated by a critical error icon
at the top of the
Unity Dashboard
.
Click the icon for details.
Figure 1-23: Power supply failure error from the Dashboard
On most Unity systems, the front-panel power failure LED corresponding to the failed PSU is illuminated, and
the status LED on the back of the PSU is either red or off.