4.5. Installation of the Local Area Network
Up to three 10/100 Mbps and two 10/100/1000 Mbps Ethernet devices can be directly con-
nected to the router, further devices can be attached via an addtional Ethernet switch.
Please ensure that the connector has been plugged in properly to
ETH
and remains in a fixed
state, you might otherwise experience sporadical link loss during operation. The Link/Act
LED will lit up as soon as the device has synced. If not, it might be necessary to configure a
different link setting as described in chapter
By default, the router is configured as a DHCP server and has the IP address 192.168.1.1.
Attention:
Only a shielded Ethernet cable may be used.
To guarantee the IP65 protection class the cable and the connector have also
to be IP65 certified. The connector has to screwed on with 0.4Nm.
If no cable is connected ensure that the M12 Cap is mounted with 0.4Nm
4.6. Installation of the Power Supply
The router must be powered with an external source supplying between 24 V
DC
and 48 V
DC
or
72 V
DC
and 110 V
DC
respectively.
First connect the power supply cable to the router. Then connect the plug-in power supply
to the supply network socket. The router is now ready for getting engaged.
Attention:
Only CE-compliant power supplies with a current-limited SELV out-
put voltage range (for NetModule routers with "Pb" option with a correspond-
ingly higher output voltage range and in accordance with appropriate compa-
rable safety precautions) may be used with the NetModule routers
33