When the reboot is complete, the Tasks tab looks like the following screenshot:
Related tasks
Accessing SANtricity System Manager
Related information
Upgrading SANtricity OS
NetApp Downloads: SANtricity OS
Monitoring and troubleshooting StorageGRID
Replacing a storage controller
You might need to replace an E2800 controller or an EF570 controller if it is not functioning
optimally or if it has failed.
Before you begin
•
You have a replacement controller with the same part number as the controller you are replacing.
•
You have labels to identify each cable that is connected to the controller.
•
You have an ESD wristband, or you have taken other antistatic precautions.
•
You have a #1 Phillips screwdriver.
•
You have the E-Series instructions for replacing a controller in duplex configuration.
Attention:
Refer to the E-Series instructions only when directed or if you need more details to
perform a specific step. Do not rely on the E-Series instructions to replace a controller in the
StorageGRID appliance, because the procedures are not the same.
About this task
You can determine if you have a failed controller in two ways:
•
The Recovery Guru in SANtricity System Manager directs you to replace the controller.
•
The amber Attention LED on the controller is on, indicating that the controller has a fault.
Attention:
If both controllers in the shelf have their Attention LEDs on, contact technical
support for assistance.
Maintaining the SG6000 appliance | 87