3. Press  the  button  on  the  new  radio  control  device  to  be 

assigned to the actuator. The activator pilot light will start 

to flash as soon as the key is released.

4. The pilot light should stop flashing.
5. Programming is now complete. All commands  are ready for normal function. 

Memorising commands for the radio operated P2/R rain sensor 

The 

P2/R

rain sensor commands all memorised motors within 60m out in the open

area 

(walls, metal panels, iron cages etc all drastically reduce capacity).

Memorising  commands for  the  radio  operated 

P2/R

rain  sensor  for  the  KATO 

RADIO  actuator  follows  a  similar  procedure  to  that  used  for  the  radio  operated 

remote control, as follows:

A. Set  dip-switch  n° 

1

to 

ON.

The  red  led  pilot  light  will  t urn  on.  Set  the  dip -

switch immediately to 

OFF

.

B. Touch the sensitive area of the sensor 

(shaped in the form of the letter N)

with  your  hand  or  a  wet  cloth for  around  1  second.  There  is  no 

danger  of 

electrical shock as the sensitive area has no electricity su pply.

C. The led pilot light will stop flashing .
D. Programming is complete. The rain sensor will be ready to function in 2 minutes

.

PROGRAMMING THE ACTUATOR
The actuator  comes out of factory “NOT PROGRAMMED”

. It must be programmed 

to apply commands from the ra dio operated remote control or rain sensor and must 

also be programmed to stop at the end course point required by the user.
Programming is carried out using the dip -switches 

(4 in total)

on the side of the actuator 

opposite the feeder cable. On the left o f the opening is a led light t o indicate functions in 

course. The following designs indicate the meanings and position of the dip

-switches:

x

Programming phase…………….…….............................

x

Programming of course to 100 mm …………………………..

x

Programming of  course  to 200 mm ……………………..

x

Programming of course to 300 mm ……………………..

x

Programming of course to 400 mm ……………………..

Summary of Contents for KATO RADIO 230V

Page 1: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 1 CHAIN OPERATED ACTUATOR ____ KATO RADIO TORQUE300 N TRUCK 400 MM ELECTRICAL FEEDING 230V 50HZ INSTRUCTION MANUAL ENGLISH...

Page 2: ...ls or property Products subject to EU directives comply with the essential requirements stipulated by the latter markings mean that our products can be sold and installed throughout the European Union...

Page 3: ...ESSIBLE 7 o MEMORISING COMMANDS FOR THE RADIO OPERATED P2 R RAIN SENSOR 8 PROGRAMMING THE LIMIT SWITCHES 8 o LIMIT SWITCHES AT OPENING 9 o LIMIT SWITCHES AT CLOSURE 9 TECHNICAL INFORMATION ABOUT FUNCT...

Page 4: ...the technical data label on the device This appliance is destined exclusively for the use for which it has been designed and the manufacture cannot be held responsible for any damages incurred by imp...

Page 5: ...has been designed and produced to open and close bay or outward opening windows hopper frame windows dormer windows cupolas and skylights It has been specifically designed for providing ventilation a...

Page 6: ...information reported in this table is not binding and may be susceptible to variations without notice LABEL DATA AND MARKINGS The actuators have been assigned marking and can be sold onto the market...

Page 7: ...ntrol electronic command device is the radio operated P2 R rain sensor For installation of the P2 R rain sensor see the installation and use manual provided in the box of the sensor packaging WARNING...

Page 8: ...ately to OFF B Touch the sensitive area of the sensor shaped in the form of the letter N with your hand or a wet cloth for around 1 second There is no danger of electrical shock as the sensitive area...

Page 9: ...when the charge absorbed is more than 10 of the nominal charge In this case at maximum charge the actuator exercises a traction force of over 330N After each closure or intervention of the electrical...

Page 10: ...he inner section of the window length where the actuator will be hung is over 405 mm in length Anything shorter than this will not allow for assembly of the actuator Ensure that all load limits for th...

Page 11: ...verything is aligned both horizontall y and vertically F Mount the bracket for outward opening windows onto the moveable part of the frame in accordance with the markings indicated on the adhesive tem...

Page 12: ...Fig 8 d Attach the adhesive template to the window frame fixed part and line axis up with the centre line X traced earlier Fig 9 Warning for window frames not on the same plane cut the part of the ad...

Page 13: ...ompletely closed by checking the pressure on the weather strips n On re entry the actuator limit switch functions automatically The device exerts a trac tion force of over 300 N to guarantee perfect s...

Page 14: ...n the bracket Attach the rapid release hook to the bracket J Check that the exit of the chain is perfectly aligned with the bracket If the chain is not aligned loosen the fixing screws and reposition...

Page 15: ...frame is closed the chain terminal is at least a couple of millimetres distant from the actuator body This will ensure correct closure of the window with correct pressure on the weather stripping If...

Page 16: ...connection has unsoldered or has been disconnected Send gear motor to a Service Centre Although selection has been carried out correctly the gearmotor will not take a limit switch Programming hasn t b...

Page 17: ...rranty is valid if the buyer can present proof of purchase and has satisfied any conditions of payment accorded The guarantee of good function of the device accorded by the manufacturer is understood...

Page 18: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 18 Notes...

Page 19: ...the following standards have been applied EN60950 1992 08 EN60950 EC 1992 10 EN60950 A1 1993 EN60950 A2 1993 08 EN60950 A3 1995 10 EN60950 A3 EC1996 01 EN60950 A4 1997 03 EN60950 A11 1997 10 EN55022...

Page 20: ...rch 2006 Printed on 13 07 2006 Page 20 NEKOS S r l I 36064 MASON VICENTINO VI Via Capitoni 7 5 Phone 0039 0424 411011 Fax 0039 0424 411013 info nekos it http www nekos it Spett NEKOS S r l Via Capiton...

Reviews: