i)
Mount the actuator onto the brackets by inserting
the two openings at each side onto the
correspondi ng pins on the brackets .
j)
Rotate the actuator 90°, bring the chain terminal up
to the bracket and insert the pin into the opening on
the bracket. Insert the rapid release hook into the
bracket (
see fig.12)
.
k)
Check that the exit on the chain is perfectly al igned
with the bracket. If the chain is not aligned with the
bracket, loosen the fixing screws and reposition the
bracket correctly .
l)
Check all electrical connections with the diagram
on the label attached to the lead .
m)
Carry out a complete check of openin g and closure
of the window. Once the closure phase has been
completed, check that the window frame is
completely closed by checking the pressure on the
weather strips .
n)
On re-entry the actuator limit switch functions
automatically. The device exerts a trac tion force of
over 300 N to guarantee perfect sealing up of the
weather strips .
Assembly of actuator onto bay or outward opening
window.
A.
Pencil in an “X” over the centre line of the window
frame
(fig. 13)
.
B.
Select the correct form of brackets
(fig. 14)
.
C.
Fold the adhesive template along the green dotted
line and keep in position at 90°. Attach one part to
the window frame
(fixed part),
taking care to line up
the axis with the “X” previously pencilled in on the
central line and line the folded part up aga inst the
moveable part of the frame.
Warning
: as various
different applications are possible, place the
actuator in a central position and adjust the
positions of the brackets, taking care to keep the
actuator aligned with the window section .
D.
Bore holes i nto the window frame at the points
indicated
(fig. 15)
.
Fig. 12
Fig. 14
Fig. 15
Fig. 13