i)

Mount  the  actuator  onto  the  brackets  by  inserting 

the  two  openings  at  each  side  onto  the 

correspondi ng pins on the brackets .

j)

Rotate the actuator 90°, bring the chain terminal up 

to the bracket and insert the pin into the opening on 

the  bracket. Insert  the  rapid  release  hook  into  the 

bracket (

see fig.12)

.

k)

Check that the exit on the chain is perfectly al igned 

with the bracket. If the chain is not aligned with the 

bracket, loosen the fixing screws and reposition the 

bracket correctly .

l)

Check  all  electrical  connections  with  the  diagram 

on the label attached to the lead .

m)

Carry out a complete check of openin g and closure 

of the  window.  Once  the  closure  phase  has  been 

completed,  check  that  the  window  frame  is 

completely closed by checking the pressure on the 

weather strips .

n)

On  re-entry  the  actuator  limit  switch  functions 

automatically. The device exerts a trac tion force of 

over 300 N to guarantee perfect sealing up of the 

weather strips .

Assembly of actuator onto bay or outward opening 

window.

A.

Pencil in an “X” over the centre line of the window 

frame 

(fig. 13)

.

B.

Select the correct form of brackets 

(fig. 14)

.

C.

Fold the adhesive template along the green dotted 

line and keep in position at 90°. Attach one part to 

the window frame 

(fixed part), 

taking care to line up 

the axis with the “X” previously pencilled in on the 

central line and line the folded part up aga inst the 

moveable  part  of  the  frame. 

Warning

:  as  various 

different  applications  are  possible,  place  the 

actuator  in  a  central  position  and  adjust  the 

positions  of  the  brackets,  taking  care  to  keep  the 

actuator aligned with the window section .

D.

Bore  holes  i nto  the  window  frame  at  the  points 

indicated

(fig. 15)

.

Fig. 12

Fig. 14

Fig. 15

Fig. 13

Fig. 16

Summary of Contents for KATO RADIO 230V

Page 1: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 1 CHAIN OPERATED ACTUATOR ____ KATO RADIO TORQUE300 N TRUCK 400 MM ELECTRICAL FEEDING 230V 50HZ INSTRUCTION MANUAL ENGLISH...

Page 2: ...ls or property Products subject to EU directives comply with the essential requirements stipulated by the latter markings mean that our products can be sold and installed throughout the European Union...

Page 3: ...ESSIBLE 7 o MEMORISING COMMANDS FOR THE RADIO OPERATED P2 R RAIN SENSOR 8 PROGRAMMING THE LIMIT SWITCHES 8 o LIMIT SWITCHES AT OPENING 9 o LIMIT SWITCHES AT CLOSURE 9 TECHNICAL INFORMATION ABOUT FUNCT...

Page 4: ...the technical data label on the device This appliance is destined exclusively for the use for which it has been designed and the manufacture cannot be held responsible for any damages incurred by imp...

Page 5: ...has been designed and produced to open and close bay or outward opening windows hopper frame windows dormer windows cupolas and skylights It has been specifically designed for providing ventilation a...

Page 6: ...information reported in this table is not binding and may be susceptible to variations without notice LABEL DATA AND MARKINGS The actuators have been assigned marking and can be sold onto the market...

Page 7: ...ntrol electronic command device is the radio operated P2 R rain sensor For installation of the P2 R rain sensor see the installation and use manual provided in the box of the sensor packaging WARNING...

Page 8: ...ately to OFF B Touch the sensitive area of the sensor shaped in the form of the letter N with your hand or a wet cloth for around 1 second There is no danger of electrical shock as the sensitive area...

Page 9: ...when the charge absorbed is more than 10 of the nominal charge In this case at maximum charge the actuator exercises a traction force of over 330N After each closure or intervention of the electrical...

Page 10: ...he inner section of the window length where the actuator will be hung is over 405 mm in length Anything shorter than this will not allow for assembly of the actuator Ensure that all load limits for th...

Page 11: ...verything is aligned both horizontall y and vertically F Mount the bracket for outward opening windows onto the moveable part of the frame in accordance with the markings indicated on the adhesive tem...

Page 12: ...Fig 8 d Attach the adhesive template to the window frame fixed part and line axis up with the centre line X traced earlier Fig 9 Warning for window frames not on the same plane cut the part of the ad...

Page 13: ...ompletely closed by checking the pressure on the weather strips n On re entry the actuator limit switch functions automatically The device exerts a trac tion force of over 300 N to guarantee perfect s...

Page 14: ...n the bracket Attach the rapid release hook to the bracket J Check that the exit of the chain is perfectly aligned with the bracket If the chain is not aligned loosen the fixing screws and reposition...

Page 15: ...frame is closed the chain terminal is at least a couple of millimetres distant from the actuator body This will ensure correct closure of the window with correct pressure on the weather stripping If...

Page 16: ...connection has unsoldered or has been disconnected Send gear motor to a Service Centre Although selection has been carried out correctly the gearmotor will not take a limit switch Programming hasn t b...

Page 17: ...rranty is valid if the buyer can present proof of purchase and has satisfied any conditions of payment accorded The guarantee of good function of the device accorded by the manufacturer is understood...

Page 18: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 18 Notes...

Page 19: ...the following standards have been applied EN60950 1992 08 EN60950 EC 1992 10 EN60950 A1 1993 EN60950 A2 1993 08 EN60950 A3 1995 10 EN60950 A3 EC1996 01 EN60950 A4 1997 03 EN60950 A11 1997 10 EN55022...

Page 20: ...rch 2006 Printed on 13 07 2006 Page 20 NEKOS S r l I 36064 MASON VICENTINO VI Via Capitoni 7 5 Phone 0039 0424 411011 Fax 0039 0424 411013 info nekos it http www nekos it Spett NEKOS S r l Via Capiton...

Reviews: