Code 4420026
Edition no. 1 of 1
st
March 2006
Printed on 13/07/2006
Page 14
E.
Mount the bracket for outward opening windows onto the moveable part of
the frame in accordance with the markings indicated on the adhesive
template .
F.
Complete assembly of the chain terminal with the
rapid release hook
inserted onto the provided pin Ø4x32 in median position
(see fig. 16
)
.
G.
Mount the two brackets on to the sides of the actuator .
H.
Position the actuator onto the window frame and line up with the holes
bored earlier. Fix the actuator in posi tion with the screws provided .
I.
Bring the chain terminal up to the bracket and insert the pin into the hole on
the bracket. Attach the rapid release hook to the bracket .
J.
Check that the exit of the chain is perfectly aligned with the bracket. If the
chain is not aligned, loosen the fixing screws and reposition the bracket
correctly .
K.
Check all electrical connections with the diagram on the label attached to
the lead .
L.
Carry out a complete check of opening and closure of the window. Once
the closure phase has be en completed, check that the window frame is
completely closed by checking the pressure on the weather strips
.
M.
On re-entry the actuator limit switch functions automatically. The device
exerts a traction force of over 300 N to guarantee perfect sealing up o
f the
weather strips .
ELECTRICAL CONNECTIONS
The cable supplied with the actuator is around 2 m long (±5%) and complies with
safety standard regulations. See the diagram below for wiring.