Code 4420026
Edition no. 1 of 1
st
March 2006
Printed on 13/07/2006
Page 12
L.
Carry out a complete check of opening and closure
of the window. Once the closure phase has been
completed, check that the window frame is
completely closed by checking the pressure on the
weather strips .
M.
On re-entry the actuator limit switch functions
automatically. The device exerts a tract ion force of
over 300 N to guarantee perfect sealing up of the
weather strips .
Assembly on transom window
a)
Before starting, check that there are at least two
mechanical compass safety stops or other form of
stops connected to the frame, and ensure that th e
stops can prevent any accidental fall of the window.
Your safety is at hand .
b)
Pencil in an “X” over the centre line of the window
frame (
Fig. 7
).
c)
Select the correct form of brackets
(Fig. 8)
.
d)
Attach the adhesive template to the window frame
(fixed part)
and line axis up with the centre line “X”
traced earlier
(Fig. 9)
.
Warning
: for window frames
not on the same plane, cut the part of the adhesive
template coloured in grey and fix this to the
moveable part of the window frame, taking care to
keep it in th e same position .
e)
Bore holes in the window frame at the points
indicated on the adhesive template
(Fig. 10)
.
f)
Assemble the two brackets with the distancer
(to
help position correctly. Once it has served its
purpose it can be removed)
. Mount the supports
onto the frame with the appropriate screws
provided. Check that everything is aligned both
horizontally and vertically .
g)
Mount the bracket for outward opening windows
onto the moveable part of the frame in accordance
with the markings indicated on the adhes ive
template .
h)
Complete assembly of the chain terminal with the
rapid release hook inserted onto the provided pin
Ø4x32 in median position
(see fig. 11)
.