Code 4420026
Edition no. 1 of 1
st
March 2006
Printed on 13/07/2006
Page 16
TROUBLESHOOTING
Please consult the following table for any eventual problems with function during
installation or normal use :
Problem
Possible cause
Solution
Actuator doesn’t
work
x
No electricity supply for
feeder.
x
Connecting cable not
connected or wire not
connected.
x
Winder on the transformer is
broken.
x
Check state of safety
switch.
x
Check all electrical
connections of gear motor.
x
Replace the electronics
card of the feeder.
LED is lit but
actuator doesn’t
work.
Gear motor is damaged due to
a shock. Motor connection has
unsoldered or has been
disconnected.
Send gear motor to a Service
Centre.
Although selection
has been carried
out correctly the
gearmotor will not
take a limit switch.
Programming hasn’t been
carried out correctly.
Irregular function or break in
the electrical contact for the
dip-switch.
Repeat programming for dip -
switch.
Send gear motor to a Service
Centre.
Actuator does not
move.
The radio command has not
been accepted by the radio
receiver.
Repeat the memorisation
procedure for the radio
command.
Rain sensor does
not close window.
Sensor has not been accepted
by the radio receiver.
The sensor is not a radio
operated
P2/R
model.
(May only be the P2 model
which looks exactly the same).
Repeat the memorisation
procedure for the rain sensor.
Replace the sensor with the
P2/R
model.