TECHNICAL DATA

MODEL

KATO RADIO 230V

Pressure torque

300 N

Traction torque

300 N

Track runs 

(can be selected at any time)

100, 200, 300, 400 mm

Voltage

230V~ 50 Hz

Current consumption at nominal charge

0,115 A

Charge absorbed at nominal load

~ 28 W

No load speed

10 mm/s

No load duration 

(400 mm)

40 s

Double electrical insulation

YES

Type of service

S

2

of

3 min

Working temperature

- 5  + 65 ºC

Protection index

IP30

Adjustment of socket at casing

Autopositioning

Connection of two or more devices in para llel

YES

Limit switch stop at opening

Electronic

Limit switch stop at closure

At absorption of charge

Dimensions

386,5x59x37

Weight

0,970 Kg

Any information reported in this table is not binding and may be susceptible to 

variations without notice

LABEL DATA AND MARKINGS

The  actuators  have  been  assigned 

marking  and  can  be

sold  onto  the  market  and  used  throughout  European  Union 

territory without further requirement.
The 

marking on the product, packag ing and user warnings 

indicate  “

presumed  conformity  to  directives

”  issued  by  the 

EEC.
The 

manufacturer 

holds 

technical 

archives 

with 

documentation to prove that products have been examined to 

assess conformity to directives.
Rating plate data is located on an adhesive polyethylene label 

on  the  outside  of  the  container,  printed  in  blue  on  a  grey 

background.  All  data  conform  to  stipulations  required  by 

community standards in force.

ELECTRICITY SUPPLY

The only electrical connection on the actuator is for conne ction to the electricity 

supply at 230V~ 50Hz 

(AC) 

by connecting the two wires 

(

L

(phase) 

N

(neutral))

on 

Summary of Contents for KATO RADIO 230V

Page 1: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 1 CHAIN OPERATED ACTUATOR ____ KATO RADIO TORQUE300 N TRUCK 400 MM ELECTRICAL FEEDING 230V 50HZ INSTRUCTION MANUAL ENGLISH...

Page 2: ...ls or property Products subject to EU directives comply with the essential requirements stipulated by the latter markings mean that our products can be sold and installed throughout the European Union...

Page 3: ...ESSIBLE 7 o MEMORISING COMMANDS FOR THE RADIO OPERATED P2 R RAIN SENSOR 8 PROGRAMMING THE LIMIT SWITCHES 8 o LIMIT SWITCHES AT OPENING 9 o LIMIT SWITCHES AT CLOSURE 9 TECHNICAL INFORMATION ABOUT FUNCT...

Page 4: ...the technical data label on the device This appliance is destined exclusively for the use for which it has been designed and the manufacture cannot be held responsible for any damages incurred by imp...

Page 5: ...has been designed and produced to open and close bay or outward opening windows hopper frame windows dormer windows cupolas and skylights It has been specifically designed for providing ventilation a...

Page 6: ...information reported in this table is not binding and may be susceptible to variations without notice LABEL DATA AND MARKINGS The actuators have been assigned marking and can be sold onto the market...

Page 7: ...ntrol electronic command device is the radio operated P2 R rain sensor For installation of the P2 R rain sensor see the installation and use manual provided in the box of the sensor packaging WARNING...

Page 8: ...ately to OFF B Touch the sensitive area of the sensor shaped in the form of the letter N with your hand or a wet cloth for around 1 second There is no danger of electrical shock as the sensitive area...

Page 9: ...when the charge absorbed is more than 10 of the nominal charge In this case at maximum charge the actuator exercises a traction force of over 330N After each closure or intervention of the electrical...

Page 10: ...he inner section of the window length where the actuator will be hung is over 405 mm in length Anything shorter than this will not allow for assembly of the actuator Ensure that all load limits for th...

Page 11: ...verything is aligned both horizontall y and vertically F Mount the bracket for outward opening windows onto the moveable part of the frame in accordance with the markings indicated on the adhesive tem...

Page 12: ...Fig 8 d Attach the adhesive template to the window frame fixed part and line axis up with the centre line X traced earlier Fig 9 Warning for window frames not on the same plane cut the part of the ad...

Page 13: ...ompletely closed by checking the pressure on the weather strips n On re entry the actuator limit switch functions automatically The device exerts a trac tion force of over 300 N to guarantee perfect s...

Page 14: ...n the bracket Attach the rapid release hook to the bracket J Check that the exit of the chain is perfectly aligned with the bracket If the chain is not aligned loosen the fixing screws and reposition...

Page 15: ...frame is closed the chain terminal is at least a couple of millimetres distant from the actuator body This will ensure correct closure of the window with correct pressure on the weather stripping If...

Page 16: ...connection has unsoldered or has been disconnected Send gear motor to a Service Centre Although selection has been carried out correctly the gearmotor will not take a limit switch Programming hasn t b...

Page 17: ...rranty is valid if the buyer can present proof of purchase and has satisfied any conditions of payment accorded The guarantee of good function of the device accorded by the manufacturer is understood...

Page 18: ...Code 4420026 Edition no 1 of 1 st March 2006 Printed on 13 07 2006 Page 18 Notes...

Page 19: ...the following standards have been applied EN60950 1992 08 EN60950 EC 1992 10 EN60950 A1 1993 EN60950 A2 1993 08 EN60950 A3 1995 10 EN60950 A3 EC1996 01 EN60950 A4 1997 03 EN60950 A11 1997 10 EN55022...

Page 20: ...rch 2006 Printed on 13 07 2006 Page 20 NEKOS S r l I 36064 MASON VICENTINO VI Via Capitoni 7 5 Phone 0039 0424 411011 Fax 0039 0424 411013 info nekos it http www nekos it Spett NEKOS S r l Via Capiton...

Reviews: