P2595EN01
08 - 2007
Minimum level of tubes
This function is used for setting the number of coins (0 to 15) to determine the status of full change tubes and
the "Insert exact amount" message for the user.
Accepted bills
It is possible to define which, among the bills recognised by the reader, are to be accepted.
Check the reader configuration for the correct bill to value matching.
Accepted coins with "exact amount"
It is possible to define which, among the coins recognised by the coin mechanism, are to be accepted when
the machine is in the "exact amount" condition.
Check the coin mechanism configuration for the correct coin to value matching.
Accepted bills with "exact amount"
It is possible to define which, among the bills recognised by the accepter, are to be accepted when the ma
-
chine is in the "exact amount" condition.
Check the accepter's configuration for the correct bill to value matching.
Cashless Private / undefined Credit Control
This function is used for showing or not on the display the credit present in the cashless system, replacing it
with the string "-----". The same string is displayed also in the event where the credit of the cashless system is
not defined.
Overpay
Thus function is used for setting the management of credit excess.
Credit excess is a credit that cannot be returned to the user; for example in the event of failing to return the
change due to insufficient minimum level in the tubes.
If set as MAINTAINED any credit excess remains available to the user.
If set as CANCELLED, it permits to maintain the credit excess for a programmable time before cashing it.
Cash sale
This function is used for setting the management of messages for sales made with cash for statistical
purposes.
0
-
The data is sent as per MDB protocol
1
-
The sales data is sent by overriding to the cashless system 1
2
-
The sales data is sent by overriding to the cashless system 2
Parallel Device
This function permits the use of a coin or bill validator in place of an MDB Changer (coins) or MDB Bill
Validator (banknotes).
The replaced MDB device, after resetting the machine, will no longer be used.
Exact change equation
This value defines the combination of empty coin tubes, setting the coin mechanism in "exact amount" mode.
The possible combinations of empty coin tubes are indicated below.
For greater simplicity, the combination is described with reference to tubes A, B and C, where tube A receives
the lower value coins and tube C the greater value coins.
0
=
A or (B and C)
1
=
A and B and C
2
=
A and B only
3
=
A and (B or C)
4
=
A only
5
=
A or B only (default)
6
=
A or B or C
7
=
A or B only
8
=
A or C only
9
=
B and C only
10
=
B only
11
=
B or C only
12
=
C only
c
oIn
m
echanIsm
s
ettIngs
46