![Necta brio 3 Programming Manual Download Page 23](http://html.mh-extra.com/html/necta/brio-3/brio-3_programming-manual_715402023.webp)
P2595EN01
08 - 2007
TECHnICIAn MEnu
18
2.3 - MACHINE PARAM.
2.3.1 - BOILER TEMPERAT.
2.3.2 - TANK
2.3.3 - MIXER HEATING
2.3.4 - MIXER COOLING
2.3.5 - FAST CYCLES
2.3
v
endIng
machIne
Parameters
2.3.1
b
oIler
temPerature
This function is used for setting the operating temperature, ex-
pressed in °C, of the boilers actually installed in the machine.
After selecting the boiler, press the confirm button “
�
”, the tempera-
ture value on the display will start blinking and can be modified as
necessary.
2.3.2
t
ank
The machine water supply can be from the mains or from an internal
tank. For some applications it is also possible to use two internal
tanks at the same time.
With this function it is possible to define whether the machine water
supply is from the mains (tank = 0) or from the tanks (tank = 1 or 2).
2.3.3
m
Ixer
heatIng
With this function it is possible to heat the mixer with a small amount
of hot water before dispensing, as long as the following conditions
are met:
- the first water dose composing the drink is below 60 cc;
- no hot drinks have been dispensed from the mixer in the last 3 min-
utes, or no cold drinks have been dispensed in the last 5 minutes.
2.3.4
m
Ixer
coolIng
(
only
for
machInes
wIth
a
cold
unIt
)
With this function it is possible to cool the mixer with a small amount
of cold water before dispensing, if no cold drinks have been dis-
pensed from the mixer in the last 5 minutes, or no hot drinks have
been dispensed in the last 3 minutes.
2.3.5
f
ast
cycles
When this function is enabled, some of the time that is useful for
improving the drink quality is eliminated: all products that compose
the drink are dispensed at the same time, eliminating the “post-
whipping” time.