TECHnICIAn MEnu
19
2.3.6 - SET DISP. MAINT.
2.3.7 - PHOTOCELL
2.3.8 - NEON TIME
2.3.9 - SET CUP SETTLING
2.3.A - EN. WASH BUTTON
2.3.B - EN.AUT.MIX.WASH
2.3.6
s
ettIng
the
regeneratIon
counter
It is possible to display the message “Regenerate the water sof-
tener” upon accessing “Filler” mode after a programmable number
of drinks dispensed.
2.3.7
P
hotocell
The machine can be fitted with a “cup sensor” composed of pho
-
tocell that detects the presence of an object in the dispensing
compartment.
When the function is enabled, if an object is detected in the dis-
pensing compartment, a cup is not released and the display indi-
cates the message “Without cup”.
It is also possible to define whether, after two attempts to release
a cup without the photocell detecting any objects in the dispensing
compartment; the failure should lock the machine or leave it to oper-
ate using a ceramic cup.
A lighting lamp inside the dispensing compartment is controlled by
the cup sensor.
If the cup is still inserted, when the next selection is made the mes-
sage "Remove cup" is displayed.
2.3.8
e
quIPPed
base
cabInet
In the event the machine is equipped with a dispensing compart-
ment lamp. With this function it is possible to define how long
(programmable between 0 and 300 t/s) the lighting lamp inside the
dispensing compartment is to stay on, if the cup sensor is not fitted.
2.3.9
c
uP
settlIng
tIme
This function is used for setting the delay time in stopping the cup
column rotation in order to compensate any inertia due to the cup
type.
2.3.a
e
nablIng
the
wash
button
With this function it is possible to enable the operation of the mixer
wash button.
Normally the button is disabled.
2.3.b
a
utomatIc
mIxer
wash
It is possible to set the time when performing an automatic mixer
wash cycle. When setting the time to 24.00 the function is disabled
(default).