![Necta brio 3 Programming Manual Download Page 13](http://html.mh-extra.com/html/necta/brio-3/brio-3_programming-manual_715402013.webp)
P2595EN01
08 - 2007
FILLER MEnu
8
4 - BOILER TEMPERAT.
5 - TEST
5.1 - COMP. DISPENSING
5.2 - WATER ONLY
4
b
oIler
temPerature
This function is used for displaying the operating temperature, ex-
pressed in °C, of the boilers actually installed in the machine.
5
t
est
5.1
c
omPlete
dIsPensIng
With this function it is possible to obtain, with the door open
and without inserting any money, complete dispensing for each
selection.
5.2
w
ater
only
With this function it is possible to dispense, with the door open
and without inserting any money, only the water doses for each
selection.
5.3
P
owder
only
With this function it is possible to dispense, with the door open
and without inserting any money, only the powder doses for each
selection.
5.3 - POWDER ONLY
5.4 - NO ACCESSORIES
5.5 - ACCESSORIES ONLY
5.4
n
o
accessorIes
With this function it is possible to dispense, with the door open and
without inserting any money, only the water and powder doses for
each selection, without any cup and stirrer.
5.5
a
ccessorIes
only
With this function it is possible to dispense, with the door open
and without inserting any money, only the accessories for each
selection.