UNIVERGE UM8500 I
NTEGRATION
G
UIDE
34
To add voice mail ports to CallManager version 3.2 and
later
Add one voice mail port to CallManager for each port being connecting to
UM8500.
1
In the Cisco CallManager Administration program, select
Features
>
Voice
>
Cisco Voice Mail Ports
.
2
Click
<Add new port>
.
3
At the Configuration screen, enter values as shown in the table below.
4
Click
Insert
to save the changes.
5
Repeat steps
to specify values for each additional port.
6
Close the CallManager Administration program, then continue with the
following procedure, “
To specify MWI extensions in CallManager version 3.2
CAUTION
Voice mail ports and phones must be in the same calling search
space, or the integration will not work.
Field
Value
Port name
A name for the voice mail port, for example, “UM8500-1.” Follow these instructions:
●
In general, use the same prefix for every port, for example, “UM8500-.” However, if
CallManager is sending calls to more than one UNIVERGE UM8500 server, use a
different prefix for the CallManager ports that are being connected to each
UNIVERGE UM8500 server, for example, “UM85001-” and “UM85002-.”
●
Use prefixes that are 12 characters or less.
●
Number the ports beginning with 1 and continuing in sequence.
●
Do not begin port numbers with 0. For example, “UM8500-1” is a valid value;
“UM8500-0” is not.
CAUTION!
If a uOne port is given a device name that does not conform to
these conventions, UM8500 can not receive calls from that port.
Description
This field is automatically filled in with the name typed in the
Device name
field. These
characters can be deleted and a new description can be typed.
Device pool
Click
Default
.
Location
Accept the default value of
None
.
Directory number
The extension that will be connected to UM8500.
Forward all
This field should be left blank.
CAUTION!
Do not set a value for this field. If information appears in this field,
UM8500 might operate improperly.
Forward busy
The extension of the next voice mail port in sequence. If this extension is the last voice
mail port, then type the extension of the first voice mail port. Alternatively, the last voice
mail port can be forwarded to the operator’s extension.
If the directory number for this voice mail port is busy, calls are forwarded to the
extension shown in this field.
Forward no answer The extension of the next voice mail port in sequence. If this extension is the last voice
mail port, then type the extension of the first voice mail port. Alternatively, the last voice
mail port can be forwarded to the operator’s extension.
If the directory number for this voice mail port is not answered, calls are forwarded to the
extension shown in this field.
Forward no answer is set in the event the port is disabled or out of service.
Summary of Contents for UNIVERGE UM8500
Page 1: ......
Page 28: ...UNIVERGE UM8500 INTEGRATION GUIDE 18 ...
Page 62: ...UNIVERGE UM8500 INTEGRATION GUIDE 52 ...
Page 68: ...UNIVERGE UM8500 INTEGRATION GUIDE 58 ...
Page 94: ...UNIVERGE UM8500 INTEGRATION GUIDE 84 ...
Page 104: ...UNIVERGE UM8500 INTEGRATION GUIDE 94 ...
Page 114: ...UNIVERGE UM8500 INTEGRATION GUIDE 104 ...
Page 120: ...UNIVERGE UM8500 INTEGRATION GUIDE 110 ...
Page 126: ...UNIVERGE UM8500 INTEGRATION GUIDE 116 ...
Page 146: ...UNIVERGE UM8500 INTEGRATION GUIDE 136 ...
Page 164: ...UNIVERGE UM8500 INTEGRATION GUIDE 154 For a SPADLIC A trunk board ...
Page 172: ...UNIVERGE UM8500 INTEGRATION GUIDE 162 ...
Page 188: ...UNIVERGE UM8500 INTEGRATION GUIDE 178 ...
Page 193: ...NEC NEAX 2400 OR NEC SV7000 WITH LAN MCI 183 For a SPADLIC A trunk board ...
Page 222: ...UNIVERGE UM8500 INTEGRATION GUIDE 212 ...
Page 230: ...UNIVERGE UM8500 INTEGRATION GUIDE 220 ...
Page 276: ...UNIVERGE UM8500 INTEGRATION GUIDE 266 ...
Page 290: ...UNIVERGE UM8500 INTEGRATION GUIDE 280 ...
Page 302: ...UNIVERGE UM8500 INTEGRATION GUIDE 292 ...
Page 312: ...UNIVERGE UM8500 INTEGRATION GUIDE 302 ...
Page 336: ...UNIVERGE UM8500 INTEGRATION GUIDE 326 ...
Page 342: ...UNIVERGE UM8500 INTEGRATION GUIDE 332 ...