Leave all other parameters not listed above at their default values.
7
If using a template that enables the MCI-LAN integration, in the navigation
panel of the configuration file, expand the MCI-LAN node.
The settings must match the settings for the phone system for the MCI LAN
connection.
LAN-IP.
Enter the IP address of the phone system. This should be the same
as the address entered in the CallPilot1 section under the PBX-IP. The default
value is just an example and must be changed to match the phone system
setting.
Format.
Enter the format of the MCI-LAN packets expected from the phone
system. Enter
ICS
for regular (ICS/IVS) packets, or
IMX
for expanded (IMX)
packets. The default is IMX.
Parity.
Enter the parity or checksum used by the phone system to process
the MCI-LAN packets. Accepted values are
None
,
Even
, or
Odd
. The default
is Odd.
LocalPort.
Enter the local port used by the MCI-LAN integration module for
a TCP/IP connection to the phone system. Accepted values are any valid
TCP/IP port. The default is 60120. Do not change this value unless you know
that this port is already taken by other applications on the UNIVERGE
UM8500 server.
DeviceID.
Enter the device ID used by the MCI-LAN integration module to
identify itself to the MCI interface on the phone system. Accepted values are 0
and 1. The default is 1.
Leave all other parameters not listed above at their default values.
8
In the navigation pane of the configuration file, expand VMSystem1 node.
Set the following parameters to configure the VMSystem1 node:
Host.
Enter the IP address of the monitored UNIVERGE UM8500 server. This
will be the same IP address entered previously in the configuration ini file.
The default value is just an example.
PortRange.
Enter the port or range of ports for the PBX tenant hosting the
voice mail ports. Ports can be set by entering a single port number, for
example
xxxx
; a range of numbers, for example
xxxx-xxxx
; or a
combination or both, for example
xxxx-xxxx,x
. The default ports are just
an example.
Tenant.
Enter the PBX tenant number where the voice mail ports are set.
The default value is 1.
Leave all other parameters not listed above at their default values.
9
Click
File > Save
to save the XML configuration file.
10
Install the OAI service and test the integration.
Installing and starting the OAI service
NOTE
Do not complete this step if a template other than the NEC
SV7000 - OAI-UCD-MCI LAN template, where the PBX cmd ASYDL
Sys 1 Index 833 Bit 0 value = 1, was selected.
Summary of Contents for UNIVERGE UM8500
Page 1: ......
Page 28: ...UNIVERGE UM8500 INTEGRATION GUIDE 18 ...
Page 62: ...UNIVERGE UM8500 INTEGRATION GUIDE 52 ...
Page 68: ...UNIVERGE UM8500 INTEGRATION GUIDE 58 ...
Page 94: ...UNIVERGE UM8500 INTEGRATION GUIDE 84 ...
Page 104: ...UNIVERGE UM8500 INTEGRATION GUIDE 94 ...
Page 114: ...UNIVERGE UM8500 INTEGRATION GUIDE 104 ...
Page 120: ...UNIVERGE UM8500 INTEGRATION GUIDE 110 ...
Page 126: ...UNIVERGE UM8500 INTEGRATION GUIDE 116 ...
Page 146: ...UNIVERGE UM8500 INTEGRATION GUIDE 136 ...
Page 164: ...UNIVERGE UM8500 INTEGRATION GUIDE 154 For a SPADLIC A trunk board ...
Page 172: ...UNIVERGE UM8500 INTEGRATION GUIDE 162 ...
Page 188: ...UNIVERGE UM8500 INTEGRATION GUIDE 178 ...
Page 193: ...NEC NEAX 2400 OR NEC SV7000 WITH LAN MCI 183 For a SPADLIC A trunk board ...
Page 222: ...UNIVERGE UM8500 INTEGRATION GUIDE 212 ...
Page 230: ...UNIVERGE UM8500 INTEGRATION GUIDE 220 ...
Page 276: ...UNIVERGE UM8500 INTEGRATION GUIDE 266 ...
Page 290: ...UNIVERGE UM8500 INTEGRATION GUIDE 280 ...
Page 302: ...UNIVERGE UM8500 INTEGRATION GUIDE 292 ...
Page 312: ...UNIVERGE UM8500 INTEGRATION GUIDE 302 ...
Page 336: ...UNIVERGE UM8500 INTEGRATION GUIDE 326 ...
Page 342: ...UNIVERGE UM8500 INTEGRATION GUIDE 332 ...