141
Programming
the phone
system
If programming options other than those described in the following procedures
are used, the integration’s performance can be affected.
To program the digital voice messaging ports in the
phone system
1
Specify a Service Feature Restriction Class (SFC) for the voice messaging ports
by using the ASFC command. It is recommended that all of the voice
messaging ports be placed in a single SFC not used for any other purpose.
The following Service Feature Indexes (SFIs) are needed in the SFC:
2
Assign a value of
26
to the Telephone Equipment Class (TEC) for each voice
messaging port by using the ASDT command. Use the SFC created for the
voice messaging ports in step
.
3
Assign all of the voice messaging ports to a Uniform Call Distribution (UCD)
group.
If the number of voice messaging system ports exceeds the number of
supported ports in a UCD group, specify additional UCD groups, then link
them together using the AUOG command.
4
Program each phone to forward calls to the UCD pilot number assigned to
the voice messaging ports, based on the UM8500 call transfer type:
Release to switch transfer.
Program the phone to forward calls to the
UCD pilot number when:
■
The extension is busy; or,
■
The call is not answered.
Supervised transfer.
Program the phone to forward calls to the UCD pilot
number only when the call is not answered. Confirm that call forwarding is
disabled when the extension is busy.
NOTE
The following procedures are written on the assumption that you
will use a Maintenance Administration Terminal (MAT) to program
the phone system.
SFI
Service feature
10
Call hold
103
Assignment of no answer timer for blind transfer
to station or blind transfer to attendant
104
Blind transfer
NOTE
Software versions 7200 or later support up to 100 ports in a UCD
group while software versions earlier than 7200 support up to 20
ports in a UCD group.
CAUTION
Do not use a phantom single line extension for the UCD pilot
number.
Summary of Contents for UNIVERGE UM8500
Page 1: ......
Page 28: ...UNIVERGE UM8500 INTEGRATION GUIDE 18 ...
Page 62: ...UNIVERGE UM8500 INTEGRATION GUIDE 52 ...
Page 68: ...UNIVERGE UM8500 INTEGRATION GUIDE 58 ...
Page 94: ...UNIVERGE UM8500 INTEGRATION GUIDE 84 ...
Page 104: ...UNIVERGE UM8500 INTEGRATION GUIDE 94 ...
Page 114: ...UNIVERGE UM8500 INTEGRATION GUIDE 104 ...
Page 120: ...UNIVERGE UM8500 INTEGRATION GUIDE 110 ...
Page 126: ...UNIVERGE UM8500 INTEGRATION GUIDE 116 ...
Page 146: ...UNIVERGE UM8500 INTEGRATION GUIDE 136 ...
Page 164: ...UNIVERGE UM8500 INTEGRATION GUIDE 154 For a SPADLIC A trunk board ...
Page 172: ...UNIVERGE UM8500 INTEGRATION GUIDE 162 ...
Page 188: ...UNIVERGE UM8500 INTEGRATION GUIDE 178 ...
Page 193: ...NEC NEAX 2400 OR NEC SV7000 WITH LAN MCI 183 For a SPADLIC A trunk board ...
Page 222: ...UNIVERGE UM8500 INTEGRATION GUIDE 212 ...
Page 230: ...UNIVERGE UM8500 INTEGRATION GUIDE 220 ...
Page 276: ...UNIVERGE UM8500 INTEGRATION GUIDE 266 ...
Page 290: ...UNIVERGE UM8500 INTEGRATION GUIDE 280 ...
Page 302: ...UNIVERGE UM8500 INTEGRATION GUIDE 292 ...
Page 312: ...UNIVERGE UM8500 INTEGRATION GUIDE 302 ...
Page 336: ...UNIVERGE UM8500 INTEGRATION GUIDE 326 ...
Page 342: ...UNIVERGE UM8500 INTEGRATION GUIDE 332 ...