UNIVERGE SV8100
Issue 10.1
Programming Manual
2 - 873
40
0
0
CS error noti-
fication 2.
CS detected the factor that
the noise is generated
between CS-PS, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
50
1
0
System Start
Notification
The system started.
The system was
started.
No action needed.
51
0
0
System Data
change
CD-CP00 Upgrade is
performed or Programming
change is made.
No action needed.
52
0
0
--- Not Used ---
54
2
0
License
Management
Table Full
A new TCP/IP terminal and
the DSP board were not
able to be added to the
application license
management table.
• The license management
table is registering full.
Maximum 512
license information
on the TCP/IP
terminal is
registered, and a
new terminal
cannot be
registered.
Please delete license
information on an
unnecessary TCP/IP
terminal with PRG
90-44.
WAR
55
2
0
Regular
maintenance
exchange
notification.
The regular maintenance
exchange day has passed.
• The regular
maintenance
exchange day that
had been set with
PRG 90-51
exceeded it.
Please do the
maintenance
exchanges of pertinent
parts, and set the next
regular maintenance
exchange day with
PRG 90-51.
The excess
on the regular
maintenance
exchange day
is canceled by
changing
PRG 90-51 or
when the
function is
invalidated,
the error is
recovered.
ERR
REC
57
2
0
IP Collision
Error
Collision(01) indicates the
address programmed in
10-12-01 has been
duplicated. Collision (02)
indicates the address
programmed in 10-12-09
has been duplicated.
Collision(03) ~
Collision(10) indicates the
addresses programmed in
84-26-01 have been
duplicated. (03) is GW1 ~
(10) is GW8.
An IP address
programmed in
either 10-12-01, 10-
12-09 or 84-26 is
duplicated
somewhere on the
same segment of
the network. The
system will check
every 5 minutes
and is not a
programmable
increment.
Confirm that the
addresses assigned in
10-12-01, 10-12-09,
and 86-26 are not
duplicated anywhere
else on the network.
58
2
0
Failure of
Outbound IP
Connection
01: Programming session
is already active.
02: Not setting of IP
Address or Port.
03: Caller ID does not
match.
10: Cannot get IP Address.
11: Socket Open Error.
12: Socket Port Setting
Error.
13: TCP Session Timeout.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...