Issue 10.1
UNIVERGE SV8100
2 - 872
Program 90 : Maintenance Program
35
0
0
CS Blocking
The link of the CSIU and
CS came off.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
The error is
recovered
when
reconnecting
or exchanging
it.
ERR
REC
36
0
0
CS error
notification 1
CS detected the problem
occurring in the air
synchronous signal
between CS-CSIU, BBIC
reset was executed, and it
was restored automatically.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
37
0
0
CS
transmission
error.
Because CS had not
returned the response to
the control signal from a
main device longer than
the fixed time, it was
restored automatically
specifying reset to
concerned CS with a main
device.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
38
0
0
CSIU Dch
Error×
It was restored
automatically specifying
reset to concerned CS with
a main device because a
main device had detected
the control signal from a
main device not normally
reaching CS.
1. Outgoing noise.
2. Method of setting
up CS.
3. Wiring to
connect CSIU unit
with CS.
4. Hard defect of
CS.
5. Hard defect of
CSIU.
Confirm the following
when it happens
frequently during
operation.
1. Please confirm CS is
normally connected.
2. Please confirm the
wiring between
CSIU-CS is normal.
3. Please exchange
CS.
4. Please exchange
CSIU.
This error has
been
recovered
when it is
notified.
ERR
REC
39
0
0
CSIU trans-
mission error.
This alarm is integrated
into Communication fault
between the CD-CP00 and
other PKG, and it is not
used in SV8100.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...