Programming Manual
2 - 173
Program
15
Description
Use
Program 15-01 : Basic Extension Data Setup
to define the basic
settings for each extension.
Program 15 : Extension, Basic Setup
15-01 : Basic Extension Data Setup
Level:
SA
Input Data
Extension Number
Maximum eight digits
Item
No.
Item
Input Data
Default
Related
Program
01
Extension Name
Define the extension/
virtual extension name.
Up to 12 Characters
Up to 6 Chinese
Characters (OT)
To use Chinese
Characters use PC
Pro or WebPro (OT)
Ext.200 = STA 200
(OT)
Ext.101 = STA 101
(AU)
02
Outgoing Trunk Line
Preference
Use this option to set
the extension outgoing
Trunk Line Preference.
If enabled, the
extension user receives
trunk dial tone when
they lift the handset.
The user hears trunk
dial tone only if allowed
by Trunk Access Map
programming
(Programs 14-07 and
15-06). Refer to the
Line Preference feature
for more details.
0 = Off
1 = On
0
14-06
21-02
03
SMDR Printout
Use this option to
include or exclude the
extension in the SMDR
report.
0 = Do not print on
SMDR report
1 = Include on SMDR
report
1
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...