Connection
fault between
CD-CP00 and
other PKGs.
The error occurred when
communicating with the
package. When the
package is broken, it
recognizes it as a
communication fault.
1.The unit is not
completely
inserted.
2.The power-
supply voltage of
the system is
outside ratings.
3.The equipment
that generates the
noise in the same
power supply
system as the
power supply origin
of the system is
connected, and it
malfunctions
because of the
power supply
noise.
4.The equipment to
which it is adjacent
to of a main device,
and has put out the
radiation noise
exists, and it
malfunctions
because of the
radiation noise.
5.The chassis is
not properly
grounded.
1.Please insert the unit
firmly.
2.The power-supply
voltage must use
another power supply
when is in the range of
ratings or measuring
with the voltmeter, and
deviating from the rated
range.
3.Please use the power
supply besides the
equipment with the
possibility of the noise
source.
4.Please separate as
much as possible and
use a main device from
the equipment by which
you seem may
generate the radiation
noise.
5.Please ground the
chassis correctly.
When unit is
confirmed, the
error is
recovered.
ERR
REC
4
2
0
PKG S/W
Download
Error
The unit program could not
be downloaded normally.
The unit could not able to
be started normally.
1.The package
software is not
stored in the
downloaded USB
memory.
2.The stored
package software
is illegal.
Package
information that
was installed
before remains.
1.Delete slot
information that
corresponds by
PRG90-05-01 to delete
package information
that was installed
before.
2.There is a possibility
that the unit program is
broken though an
external factor of the
noise etc. is thought.
3.Please load into the
USB memory and try
again when you back
up the unit program.
4.PleaseCheck with
maker on uncertain
points.
Please
exchange
units, though
it is likely to
restore by
mounting the
unit again.
When the unit
program is
normally
downloaded,
the error is
recovered.
ERR
REC
5
1
0
Cooling fan
error
The cooling fan does not
work normally.
1.The cooling fan
has stopped
working.
2.The cooling fan
has come off.
1.Confirm the cooling
fan is turning.
2.Verify the cooling fan
mounting.
Replace the
cooling fan if it
is defective.
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
Summary of Contents for Univerge SV8100
Page 1: ...Programming Manual NECIC AP 002 Issue 10 1 R9 5 ...
Page 105: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 69 Feature Cross Reference None ...
Page 184: ...Issue 10 1 UNIVERGE SV8100 2 148 Program 13 Abbreviated Dialing ...
Page 440: ...Issue 10 1 UNIVERGE SV8100 2 404 Program 25 VRS DISA Setup THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 566: ...Issue 10 1 UNIVERGE SV8100 2 530 Program 42 Hotel Setup Feature Cross Reference Hotel Motel ...
Page 589: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 553 Feature Cross Reference None ...
Page 658: ...Issue 10 1 UNIVERGE SV8100 2 622 Program 47 InMail THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 682: ...Issue 10 1 UNIVERGE SV8100 2 646 Program 51 NetLink Service Feature Cross Reference None ...
Page 899: ...UNIVERGE SV8100 Issue 10 1 Programming Manual 2 863 Feature Cross Reference None ...
Page 986: ...PROGRAMMING MANUAL NEC Corporation Issue 10 1 ...