3-277
NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE TITLE:
MFC/MF-ANI TRUNK DATA
31
: Default
Y
1ST DATA
2ND DATA
DATA
MEANING
DATA
MEANING
A
37
Tone Duration (Off time) of MFC (Forward
Signal/Backward Signal)
[8300R3.5]
00
09
NONE
1 dB
Increment unit: 1 dB
10 dB
10 dB
NOTE:
A reset by CM31 Y=A>90: 0 is required after this data setting.
38
Forward signal receiver S/N ratio
[8300R3.5]
00
01
02
03
04
NONE
0 dB
-5 dB
-10 dB
-15 dB
-20 dB
-10 dB
NOTE:
A reset by CM31 Y=A>90: 0 is required after this data setting.
39
Forward signal receiver ON detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE:
A reset by CM31 Y=A>90: 0 is required after this data setting.
40
Forward signal receiver OFF detect time
[8300R3.5]
01
98
99
NONE
30 ms.
Increment unit: 15 ms.
1485 ms.
3840 ms.
30 ms.
NOTE:
A reset by CM31 Y=A>90: 0 is required after this data setting.
41
Backward signal receiver Start delay time
[8300R3.5]
00
98
99
NONE
0 ms.
Increment unit: 0.25 ms.
24.5 ms.
64 ms.
0 ms.
NOTE:
A reset by CM31 Y=A>90: 0 is required after this data setting.
Continued on next page
~
~
~
~
~
~
~
~
JANUARY/14/2011
CM31
Summary of Contents for SV8300
Page 1: ...Command Manual NWA 033623 001 ISSUE 8 1 ...
Page 8: ...vi NWA 033623 001 Rev 8 1 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...3 716 NWA 033623 001 Rev 8 1 91ch3008 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...
Page 804: ...A 32 NWA 033623 001 Rev 8 1 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 15 2011 ...