4-24 Configuring Your Server
Virtual Disk
Virtual disk is a logical drive defined in disk group. It is recognized as a physical drive by OS. The
allowable number of virtual disks is up to 16 per disk group, or up to 64 per controller.
The figure below shows a sample configuration in which the Onboard RAID Controller (LSI
Embedded MegaRAID) or Internal RAID Controller (N8103-116 equivalent) is connected with
three HDDs, creating one Disk Group. Two RAID5 virtual disks (VD) are defined in the Disk
Group.
HDD 1
(36 GB)
HDD 2
(36 GB)
HDD 3
(36 GB)
RAID Controller
DG0 108 GB
VD1-3
16 GB
VD1-2
16 GB
VD1-1
16 GB
VD0-1
20GB
VD0-2
20GB
VD0-3
20GB
VD0 (RAID5)
40 GB
VD1 (RAID5)
32 GB
Parity
The parity means redundant data. A single set of redundant data is created from the data saved in
more than one HDD.
The created redundant data is used for data recovery when a HDD is defected.
Hot-Swap
The hot-swap enables a HDD to be removed (or replaced) under system operation.
Hot-Spare
The hot-spare is prepared as an auxiliary HDD substituting for a defected HDD included in a logical
drive which is configured at a redundant RAID level. Detecting a HDD fault, the system
disconnects the HDD (or makes it offline) and starts rebuild using the hot-spare.
Summary of Contents for N8100-1422F
Page 16: ...x This page is intentionally left blank...
Page 161: ...Configuring Your Server 4 93 3 Setting menu for VD 0 is displayed...
Page 238: ...7 12 Maintenance This page is intentionally left blank...
Page 356: ...C 2 IRQ This page is intentionally left blank...
Page 410: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 414: ...G 4 Product Configuration Record Table This page is intentionally left blank...