![NEC N8100-1422F User Manual Download Page 107](http://html1.mh-extra.com/html/nec/n8100-1422f/n8100-1422f_user-manual_4241305107.webp)
Configuring Your Server 4-39
Manual Rebuild
Replace hard disk drive
Run LSI Software RAID Configuration Utility
Execute rebuilding
Exit LSI Software RAID Configuration Utility
1.
Replace a hard disk drive and turn on the server.
2.
Run LSI Software RAID Configuration Utility.
3.
Select "Rebuild" from the TOP menu.
The "Rebuild – PHYSICAL DRIVES SELECTION MENU" screen appears.
4.
Move the cursor onto the hard disk drive displaying "FAIL," and then press
Space
to
select it. Multiple hard disk drives can be selected (simultaneous rebuilding.)
The "FAIL" indication for the hard disk drive selected starts blinking.
5.
When hard disk drive has been selected, press
F10
to start rebuilding.
6.
When confirmation screen for execution appears. Select "Yes".
The rebuild process starts.
When the progress bar in the "Rebuild Physical Drives in Progress" screen indicates 100%,
rebuilding is completed.
7.
Press
Esc
to return to the TOP menu and exit LSI Software RAID Configuration Utility.