Troubleshooting 8-51
Event logs in using SNMP Service in Windows Server 2003
Event Type:
Warning
Event Source:
EvntAgnt
Event Category: None
Event ID:
1015
Description:
TraceLevel parameter not located in registry;
Default trace level used is 32.
Event Type:
Warning
Event Source:
EvntAgnt
Event Category: None
Event ID:
1003
Description:
TraceFileName parameter not located in registry;
Default trace file used is .
→
The system will not be affect by these event logs. SNMP will not be affected
either, so that you can ignore these logs.
A PCI board is not recognized.
T
Is the PCI board installed correctly?
→
Confirm that the PCI board is installed in the slot correctly.
T
Is the proper IRQ assigned for the board?
→
Assign the proper IRQ by referring to Chapter 4.
T
Is "Disabled" specified in [Option ROM] for the slot to install SCSI card (excluding
the array board used for OS boot)?
→
Check the settings with the BIOS setup utility.
<Menus to check: [Advanced] - [PCI Configuration] - [PCI Slot n] (n: PCI slot
number of installed board) - [Option ROM Scan]>
T
Is "Disabled" specified in [Option ROM] for the slot for added network board which
is not used for network boot?
→
Check the settings with the BIOS setup utility.
<Menus to check: [Advanced] - [PCI Configuration] - [PCI Slot n] (n: PCI slot
number of installed board) - [Option ROM Scan]>
Summary of Contents for N8100-1223F
Page 6: ......
Page 7: ......
Page 8: ......
Page 10: ...This page is intentionally left blank...
Page 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Page 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Page 294: ...7 12 Maintenance This page is intentionally left blank...