I-Select TS100 / I-Select TW100 User Guide - Problem Solving
5 - 10
Error Messages
This section describes the POST error codes and messages.
POST Error Codes and Messages
Whenever a recoverable error occurs during POST, BIOS displays a message on the
video display screen and causes the speaker to beep as the message appears. BIOS also
issues a beep code (one long tone followed by two short tones) during POST if the
video configuration fails or if an external ROM module does not have the correct
checksum. The BIOS indicates errors by writing an error code to the PS/2-standard log-
ging area in the Extended BIOS Data Area, and by displaying a message on the screen,
which is sometimes preceded by the POST Error Code. The error code will also be
logged to the Event Logging area.
POST Error Codes and Messages
is a list of the error codes and messages written at the
start of each POST test. Table 5-2
POST Error Beep Codes
is a list of beep codes issued
for each POST test. The devices associated with the POST error codes are shown in
subsection
POST Error Code Hardware References
that follow.
Table 5 - 2: POST Error Codes And Messages
On-screen error message
Action
100
Timer Channel 2 Error
Contact your service representative to replace the system board.
101
Master Interrupt Controller
102
Slave Interrupt Controller
103
CMOS Battery Failure
104
CMOS Option not Set
Contact your service representative to replace the system board.
(Restart the computer, and then execute SETUP to correct the
setting.)
105
CMOS/GPNV Checksum
Bad
Execute SETUP to correct the setting.
106
CMOS Display Error
Contact your service representative to replace the system board.
107
Insert Key Pressed
Release the key.
108
Keyboard Locked
Message
Reconnect the keyboard.
109
Keyboard Stuck Key
Release the key. Try a different keyboard.
If the problem persists, contact your service representative to
replace the system board.
10A
Keyboard Interface Error
Reconnect the keyboard. Try a different keyboard.
If the problem persists, contact your service representative to
replace the system board.
10B
System Memory Size
Error
Install the DIMMs correctly.
Check if all the installed DIMMs are the same specification.
Contact your service representative to replace the DIMMs.
10E
External Cache Failure
Install the CPU (processor) correctly.
Contact your service representative to replace the CPU.
110
Floppy Controller Error
Contact your service representative to replace the floppy disk
drive or system board. This server does not support floppy disk
drive B.
111
Floppy A: Error